Hi Ivan,
In simple words: superdex is a few generations newer than sephadex. Main
difference: superdex is a physically and chemically, tougher medium.
Among all GE healthcare beads (or the ones I know of), superdex offers the best
resolution and mechanical strength (thus higher flow rate, very
Hi fabulous cc4bbs,
I had recently asked you about using HPLC or FPLC for protein
purification.Now I have another question relating to that. I am trying to
buy a new SEC column for the FPLC for protein purification but am getting
some resistance from some experienced people in the lab who have now
Thanks! guess I had it backwards.
eab
On 05/15/2015 03:19 PM, Yong Wang wrote:
Pymol should draw the molecular surface (or Connolly surface) by default. If you want
the solvent accessible surface, turn on the option "solvent accessible" under
Setting/Surface.
Yong
-Original Message-
Pymol should draw the molecular surface (or Connolly surface) by default. If
you want the solvent accessible surface, turn on the option "solvent
accessible" under Setting/Surface.
Yong
-Original Message-
From: CCP4 bulletin board [mailto:CCP4BB@JISCMAIL.AC.UK] On Behalf Of Edward A.
If I remember correctly, there are two different ways to calculate a surface by
rolling a ball over it, and i think that I want a program to calculate the
non-conventional one.
As I understand, the ASA is defined as the surface traced out by the _center_
of the rolling sphere, i.e. one radius
Glad it works!
It sounds like they finally fixed an X11 bug that has been quite problematic
these last few years.
Bill
William G. Scott
http://scottlab.ucsc.edu/~wgscott
> On May 14, 2015, at 9:06 PM, Xiao Lei wrote:
>
> Dear William,
>
> I installed the X11 2.7.8_rc1 as you suggested, it
thanks. :-]
2015-05-15 12:20 GMT-05:00 Marcin Wojdyr :
> Hi Murpholino
>
> On Wed, May 13, 2015 at 07:30:06PM -0500, Murpholino Peligro wrote:
> > and ubuntu/windows7 dual setup). So B and I were trying to make some
> > space...by deleting the 3GB Balbes folder (sudo rm -rf
> > /usr/local/bin/BAL
"phenix.reduce -HIS model.pdb" should do it. Use "phenix.reduce -h" to see
more options.
Pavel
On Fri, May 15, 2015 at 5:54 AM, Smith Liu wrote:
> Dear All,
>
> After CCP4 or phenix refinement, I find the H position of N in specific
> His residues needs to be regularized based on the function o
Hi Murpholino
On Wed, May 13, 2015 at 07:30:06PM -0500, Murpholino Peligro wrote:
> and ubuntu/windows7 dual setup). So B and I were trying to make some
> space...by deleting the 3GB Balbes folder (sudo rm -rf
> /usr/local/bin/BALBES).
>
> Is that the "best" way of removing BALBES?
Yes, that's a
If it helps an academic colleague of mine has been developing hi-res
full-colour 3D printed molecule models for the last 6 months or so and is very
happy to help design and make any molecules of interest. These can include
mini-magnets to click pieces together (ligand binding etc). I’ve included
Dear All,
After CCP4 or phenix refinement, I find the H position of N in specific His
residues needs to be regularized based on the function of that His.
Will you please advise on how to actively assign H to one or two of the 2 N in
the His residue in the PDB file? Or do we have a server, whi
The NIH 3D Print Exchange (http://3dprint.nih.gov/) has a collection of files
for 3D printing, and can generate files based on PDB ID.
Christine
--
Twitter: http://twitter.com/#!/buildmodels
Facebook: http://
Dear CCP4 Users
An update for the CCP4-6.5 series has just been released, consisting
of the following changes
* ARP/wARP (all platforms excluding windows)
- activation of postinstall script for standalone arp/warp
* crank2 (all platforms)
- several bugfixes
- javascript output
* jsrview (all
Dear All,
I have a fully funded PhD position to start on October 2015. The PhD will take
place at the Research Complex Harwell and Membrane Protein Lab at Diamond Light
Source, Oxfordshire. The project is the functional and structural
characterisation of a membrane protein from S. aureus.
More
Hi all,
sorry for the off-topic question, but I was wondering if any of you bought and
uses happily a “fill port” for the Akta systems which is not the “fill port,
INV-907” from GE Healthcare
(http://www.gelifesciences.com/webapp/wcs/stores/servlet/productById/en/GELifeSciences-it/18112766