-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Check the cables and that the terminator is correctly plugged in.
J.
- --Original Message--
From: Borja Tatay
To: 'John Drescher'
To: bacula-us...@lists.sf.net
Sent: Dec 20, 2008 12:04 PM
Subject: Re: [Bacula-users] Using the se
On Sat, Dec 20, 2008 at 12:04 PM, Borja Tatay wrote:
> Hi again, thanks for the help :-)
>
> I checked it and showed me this:
> ...
> [ 8611.378603] sym0: SCSI parity error detected: SCR1=1 DBC=100 SBCL=29
> [ 8611.378846] target0:0:1: control msgout: c.
> [ 8611.378967] target0:0:1: has
pt-get)
and a second hand tape library Adic Scalar 24, with two drives and SDLT-320
tapes
Thanks
-Mensaje original-
De: John Drescher [mailto:dresche...@gmail.com]
Enviado el: jueves, 18 de diciembre de 2008 15:23
Para: Borja Tatay; bacula-us...@lists.sf.net
Asunto: Re: [Bacula-users] Usin
On Thu, Dec 18, 2008 at 9:08 AM, Borja Tatay wrote:
> I've had to remove " Prefer Mounted Volumes = no " in the JobsDefs
> resource, it introduced me what I think I've read it's a bug:
>
>
>
> 18-dic 14:32 client-fd JobId 117: Fatal error: ../../filed/job.c:1811 Bad
> response to Append Data comm