Re: [Bacula-users] Q: Bacula fails to update catalog reference

2020-01-23 Thread Josh Fisher
It could be bad barcodes on some tapes or faulty/dirty barcode reader. I would think that if the barcode reader were at fault, it would affect random volumes and not the same volumes each time. If it is always the same volumes that have the issue, then maybe the barcodes on those tapes are bad.

Re: [Bacula-users] Q: Bacula fails to update catalog reference

2020-01-23 Thread Pedro Oliveira
Hi John, I suggest checking first if you are able to read the tape volumes labels outside of Bacula. on Linux shell type the following command : mtx -f "TL Changer Linux Device" status Please check the following example mtx -f /dev/changer3 status Storage Changer /dev/changer3:1 Drives, 46 S

Re: [Bacula-users] Q: Bacula fails to update catalog reference

2020-01-23 Thread Martin Simmons
If a labeled volume is missing from the catalog then either it was never added or it was deleted. Do you have any logs showing those volumes being labeled? That might give some clue. Was it done using the "label" command or by automatic labeling? Also, have you ever used the "delete volume" com