Re: [Bacula-users] Bacula crashing after move and upgrade

2010-11-22 Thread Alan Brown
Timo Neuvonen wrote: >> 1. Bacula recognizes the drives but is not reading the changer >> correctly. When trying to run "update slots" it claims to have 0 slots: >> 3306 Issuing autochanger "slots" command. >> Device "Autochanger" has 0 slots. >> No slots in changer to scan. > > > I think the ty

Re: [Bacula-users] Bacula crashing after move and upgrade

2010-11-20 Thread Eric Yellin
Issues solved: 1. Seems like I missed something with the db update. Ran updates again on the original 1.38 version upgrading up to 5.0.5 2. Changed /dev/sg0 to /dev/sg5 which turned out to be the correct device. Thanks, Eric On 20/11/2010 14:42, Timo Neuvonen wrote: "Eric Yellin"

Re: [Bacula-users] Bacula crashing after move and upgrade

2010-11-20 Thread Timo Neuvonen
"Eric Yellin" kirjoitti viestissä news:4ce6e815.1090...@migvan.co.il... >I had Bacula installed and running properly on FreeBSD for several years. > It was running Bacula 1.38. > I have an old LTO-1 HP ShureStore changer that worked fine with Bacula > 1.38 on the FreeBSD system > > I had to move t