Timo Neuvonen wrote:
>> 1. Bacula recognizes the drives but is not reading the changer
>> correctly. When trying to run "update slots" it claims to have 0 slots:
>> 3306 Issuing autochanger "slots" command.
>> Device "Autochanger" has 0 slots.
>> No slots in changer to scan.
>
>
> I think the ty
Issues solved:
1. Seems like I missed something with the db update. Ran updates again
on the original 1.38 version upgrading up to 5.0.5
2. Changed /dev/sg0 to /dev/sg5 which turned out to be the correct device.
Thanks, Eric
On 20/11/2010 14:42, Timo Neuvonen wrote:
"Eric Yellin"
"Eric Yellin" kirjoitti viestissä
news:4ce6e815.1090...@migvan.co.il...
>I had Bacula installed and running properly on FreeBSD for several years.
> It was running Bacula 1.38.
> I have an old LTO-1 HP ShureStore changer that worked fine with Bacula
> 1.38 on the FreeBSD system
>
> I had to move t