Re: [Bacula-users] Volume cycle in the bootstrap

2024-08-19 Thread Ana Emília M . Arruda
Hello Mohamed, This error means that Bacula found a "volume cycle", and the Virtual full level job cannot be run. It happens when the very same job name uses the same volumes in a loop, and it causes this issue with Virtual Full backups. Please run a Full level job instead, and you will be able

[Bacula-users] Volume cycle in the bootstrap

2024-06-24 Thread Mohamed AIT EL HADJ
Hi, Recently, i have a problem with my jobs, I got a fatal error that said : Fatal error: Found a volume cycle in the bootstrap, Virtual Full is not possible on this Job There is no other information in the logs, but i noticed that the error occurred every day at 11 p.m. Any help would be