>> Turn that feature off in the tape library's control panel.
>
> That's definitely what I'd do... you might get notified by Bacula if
> cleaning is required if you use the tape alert capturing.
>
I do this as well. Its been 2.5 years of daily usage of my 2 drive
LTO2 changer and it has yet to ask
Hi,
18.12.2008 19:17, Alan Brown wrote:
> On Thu, 18 Dec 2008, Win Htin wrote:
>
>> Hi folks,
>>
>> While Bacula backups are running, the library system (IBM TS3200) figures
>> one of the tape drives requires head cleaning and tries to load the cleaning
>> tape.
>
> Turn that feature off in the
On Thu, 18 Dec 2008, Win Htin wrote:
> Hi folks,
>
> While Bacula backups are running, the library system (IBM TS3200) figures
> one of the tape drives requires head cleaning and tries to load the cleaning
> tape.
Turn that feature off in the tape library's control panel.
Bacula can't (currently
Win
Yes, I have the same problem with my Storage Tek L700e. I just
got burned last night during a full of 300GB with the library
automatically cleaning a drive.
Only way I have been able to deal with this is to restart the job
after it fails.
I would like to know the same informati
Answering my own question. I found there is an option to disable the
"auto-clean" on the tape library. I believe the "event notification " alerts
will notify me when the next clean up is required. If not, I reckon stick to
a periodical manual clean up.
Cheers
Win
On Thu, Dec 18, 2008 at 9:53 AM,
Hi folks,
While Bacula backups are running, the library system (IBM TS3200) figures
one of the tape drives requires head cleaning and tries to load the cleaning
tape.
Following is the first email message generated from the tape-library:
-- start ---