Re: [Bacula-users] Parameters for manual tape changes

2017-02-15 Thread Kern Sibbald
Hello, This is a bug.  It is caused by having a default Volume Poll Interval of 5 minutes.  Set it to something longer or zero and the messages will go away. It would be nice if someone would submit this as a bug so that fixing it will not get

Re: [Bacula-users] Parameters for manual tape changes

2017-02-15 Thread Wanderlei Huttel
Hello Christian You can take a look in manual in teh "The Device Resource" Maximum Changer Wait = time This directive specifies the maximum time in seconds for Bacula to wait for an autochanger to change the volume. If this time is exceeded, Bacula will invalidate the Volume slot number stored in

[Bacula-users] Parameters for manual tape changes

2017-02-15 Thread lcompu...@t-online.de
Dear all kind Bacula-User-mailinglist-abonnements, I have a problem since updating from bacual 5.x to 7.4.x. I use an Tandberg LTO-5HH drive to do Backups of the local harddisks. Some of them are (at least as full backup) bigger than one single tape. I don't have the money for an autochanger