Hello Marcio,
As someone already pointed out your SD is probably running under
"bacula" and so may not have permission to access your library.
Try running with a debug level of 100 in the SD.
setdebug level=100 storage=TL1000
then add the barcode keyword to your command:
update slots barcod
On 6/14/2017 2:18 PM, Marcio Merlone wrote:
Hi,
I am running a bacula server since its 3.x series, now on version 7.4,
Ubuntu 16.04 on a Dell PE 2900 (old but gold). Just got this brand new
Dell TL1000 with 8 slots and one drive as an upgrade from the old
simple LTO-4 we have. Everything wor
One thing that I see is that your LTO-6 points to an SG device and not an
ST device. Since you now have a library I would think that you would want
bacula to reuse the tape, if so then you should use an nst device and not
the base st. The tape will rewind between jobs when you use the st device
c
Hi,
I am running a bacula server since its 3.x series, now on version 7.4,
Ubuntu 16.04 on a Dell PE 2900 (old but gold). Just got this brand new
Dell TL1000 with 8 slots and one drive as an upgrade from the old simple
LTO-4 we have. Everything works fine on bash using the mtx-changer
script,