Re: [Bacula-users] Clustering director and storage daemon.

2010-09-22 Thread James Harper
> > The only way to do tape failover is with a shared SCSI bus, AFAIK. In > theory, it should work with a shared SCSI bus system. > iSCSI should work, assuming your tape drive has an iSCSI interface or you have a SCSI<->iSCSI bridge. James --

Re: [Bacula-users] Clustering director and storage daemon.

2010-09-22 Thread Piotr Antczak
> The database and Dir work well. The SD is the tricky part. You must have > a tape drive on a shared SCSI bus, such as with Trivoli Storage Manager, > or some other means of sharing the tape library that can also provide > for a SCSI bus reset on failover. Thanks for your replay. That's exactly

Re: [Bacula-users] Clustering director and storage daemon.

2010-09-22 Thread Josh Fisher
On 9/22/2010 9:26 AM, Piotr Antczak wrote: > Hi, > I'm wondering whether it is possible to cluster dir and sd? Lets > assume that I have to nodes: node01 and node02. Each of this nodes can > access disks which are used as the file storage, can access a disk > devices on which catalog database w

[Bacula-users] Clustering director and storage daemon.

2010-09-22 Thread Piotr Antczak
Hi, I'm wondering whether it is possible to cluster dir and sd? Lets assume that I have to nodes: node01 and node02. Each of this nodes can access disks which are used as the file storage, can access a disk devices on which catalog database will reside. Each of this nodes can access SCSI tape libra