Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-31 Thread John Felczak
ets Conference and Exhibition in San Jose, CA 10/31-11/02/06 -Original Message- From: Helmut Raubenheimer [mailto:[EMAIL PROTECTED] Sent: Thursday, October 26, 2006 6:31 PM To: John Felczak Cc: bacula-users@lists.sourceforge.net Subject: Re: [Bacula-users] Bacula not loading autochanger (lot

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-26 Thread Helmut Raubenheimer
John, maybe you try the Exabyte Tools vxaTool and libTool. vxaTool for the Tape libTool for the changer Download these from Exabyte-Website. For commandline options check the readme in the archive. if libTool does not show you some information about the barcode on tape in slot 8 its a problem w

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-24 Thread Alex Chekholko
On Tue, 24 Oct 2006 12:17:06 -0700 "John Felczak" <[EMAIL PROTECTED]> wrote: > This looks quite a bit better, although still not sure why mtx keeps blanking > out on the label on the tape in slot 8. Probably because your barcode reader doesn't read that label. Does your library front panel sho

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-24 Thread John Felczak
odify mtx-changer so it looks for mtx in the right place and see if that helps. Stay tuned... John J. Felczak Build & Integration Manager Siderean Software, Inc. -Original Message- From: Robert Nelson [mailto:[EMAIL PROTECTED] Sent: Monday, October 23, 2006 10:51 PM To: 'John

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-24 Thread John Felczak
to:[EMAIL PROTECTED] Sent: Monday, October 23, 2006 10:51 PM To: 'John Felczak'; bacula-users@lists.sourceforge.net Subject: RE: [Bacula-users] Bacula not loading autochanger (lots more info) I apologize if you've already supplied this information, but would you mind attaching the

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-24 Thread John Felczak
r Siderean Software, Inc. -Original Message- From: Robert Nelson [mailto:[EMAIL PROTECTED] Sent: Monday, October 23, 2006 10:51 PM To: 'John Felczak'; bacula-users@lists.sourceforge.net Subject: RE: [Bacula-users] Bacula not loading autochanger (lots more info) I apologize if you&#x

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-24 Thread Robert Nelson
e.net Subject: Re: [Bacula-users] Bacula not loading autochanger (lots more info) Hi, On 10/24/2006 7:50 AM, Robert Nelson wrote: > I apologize if you've already supplied this information, but would you mind > attaching the output of the following three commands: > > mtx -f /d

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-24 Thread Arno Lehmann
and testing autochanger functionality by calling mtx-changer from the shell :-) Arno > -Original Message- > From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] On Behalf Of John > Felczak > Sent: Monday, October 23, 2006 3:06 PM > To: bacula-users@lists.sourceforge.net

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-23 Thread Robert Nelson
ehalf Of John Felczak Sent: Monday, October 23, 2006 3:06 PM To: bacula-users@lists.sourceforge.net Subject: Re: [Bacula-users] Bacula not loading autochanger (lots more info) Still having the same problem, but after seeing the recent thread about required information I figured I'd best includ

Re: [Bacula-users] Bacula not loading autochanger (lots more info)

2006-10-23 Thread John Felczak
Still having the same problem, but after seeing the recent thread about required information I figured I'd best include the form with the information requested. = SUPPORT === Bacula version: 1.38.9 (I had thought earlier it was 1.36.3 due to some inaccurate documentation l