Well that's what I get for reading the documentation. All the pointers
about Offline on Unmount led me down the wrong path.
Setting 'offline = 1" and "offline_sleep=10" seems to have fixed it.
nomad
___
Bacula-users mailing list
Bacula-users@lists.sourc
Does anyone else have any suggestions?
thanks,
nomad
On Fri, Jan 20, 2023 at 9:15 AM Lee Damon wrote:
> Ana, Gary,
>
> The devices were not properly owned. Changing them did not correct the
> problem, sadly. (Given the previous hardware was working with the incorrect
> owners
Ana, Gary,
The devices were not properly owned. Changing them did not correct the
problem, sadly. (Given the previous hardware was working with the incorrect
ownerships this isn't really surprising to me, though I would have loved
the quick fix had it held.)
The ownership is now bacula:bacula.
A
We recently replaced a working LTO5 + Scalar i40 jukebox with an IBM
LTO8 tape + Scalar i3 jukebox. The controller and all software remained
the same. I am suspecting a configuration problem and would greatly
appreciate guidance.
When I tried to label the new tapes it loaded the first one fine, la