[Bacula-users] Understanding Maximum Spool Size?

2013-12-04 Thread Brice Figureau
of the spool size per job (using the defaults here). Does anyone know what rules bacula is using to know when to stop spooling? (or at least a pointer to the code where I might be able to figure it out myself?) Thanks! -- Brice Figureau My Blog

[Bacula-users] Bacula restore strange error.

2008-11-12 Thread Brice Figureau
check at sd start that the currently given maximum block size is under this limit? I can file a bug report if needed. Should I? Anyway, I increased the value of this constant and I could restore this full jobs without any issue (ok that wasn't so straightforward, but I finally could restore

[Bacula-users] Variable volume retention ?

2007-02-16 Thread Brice Figureau
the cycle), my cycle starts on Tuesday, and the Incremental is promoted to Full. Everything is fine except that on next Monday, my previous Full won't be recycled... and I will for instance run out of space on my volumes/pool... Thanks for any answer, -- Brice Figureau Days of W

[Bacula-users] Boostrap file, substitution and alternate Pools...

2007-02-16 Thread Brice Figureau
e Write Bootstrap in the JobDef resource, but unfortunately there is no script parameters containing the pool name... Thanks for any help in advance! -- Brice Figureau Days of Wonder - Take Surveys. Earn Cash. Influence the F

[Bacula-users] Autochanger, double magazines, offsite backup, advice needed.

2006-11-27 Thread Brice Figureau
ole bacula documentation several time, and now, what I'm looking for is some implementation advices from the knowledgeable (and wise) system admins of this list, who are running this kind of scheme. Thank you for any help provided! -- Brice Figureau

[Bacula-users] Rerun Failed Levels not working as supposed ?

2005-04-06 Thread Brice Figureau
ot promote the job to Full or Differential because it searches for a Job that has a valid ClientId. Is it a design limitation of the Run Before Job or is it a bug ? I can file a bug report if necessary. Does anyone have a workaround (besides removing my 'Run Before Job') ? And finally ho

Re: [Bacula-users] Long timeout for connection to FD.

2005-04-01 Thread Brice Figureau
Hi, On Thu, 2005-03-31 at 19:32 +0200, Arno Lehmann wrote: > Brice Figureau wrote: > > I'm happily running Bacula 1.36.1 (switching to 1.36.2 asap), but I have > > the following problem. > > My bacula director backups a few windows user workstations every > > eveni

[Bacula-users] Long timeout for connection to FD.

2005-03-31 Thread Brice Figureau
c:773 Unable to connect to File daemon on 192.168.0.9:9102. ERR=Connection timed out 31-Mar 08:09 arsenic-dir: emmanuelle.2005-03-30_21.30.04 Error: Bacula 1.36.1 (26Nov04): 31-Mar-2005 08:09:17 [snip] Thanks, -- Brice Figureau Days of W

Re: [Bacula-users] compression=GZIP with Windows fd ?

2005-03-23 Thread Brice Figureau
Hi, On Mon, 2005-03-21 at 09:04 -0800, Karl Cunningham wrote: > --On Monday, March 21, 2005 12:38 PM +0100 Brice Figureau > <[EMAIL PROTECTED]> wrote: > > On Fri, 2005-03-18 at 11:48 -0800, Karl Cunningham wrote: > >> --On Friday, March 18, 2005 4:27 PM +0100 Brice Figu

Re: [Bacula-users] compression=GZIP with Windows fd ?

2005-03-21 Thread Brice Figureau
Hi Karl, On Fri, 2005-03-18 at 11:48 -0800, Karl Cunningham wrote: > --On Friday, March 18, 2005 4:27 PM +0100 Brice Figureau > <[EMAIL PROTECTED]> wrote: > > Does the 'compression=GZIP' FileSet option works when the file daemon is > > running on windows ? &g

[Bacula-users] compression=GZIP with Windows fd ?

2005-03-18 Thread Brice Figureau
Is the compression handled by the fd internally or with the help of a gzip executable ? In the second case, would it make the compression works if I can provide a gzip executable accessible in the windows %PATH% ? Thanks for your help, Regards, -- Brice Fig