Re: [Bacula-users] Bacula

2016-07-15 Thread Andre Rossouw
Hi, I had to add the "Maximum Console Connections" directive under the the director configuration: Director { Name = server-dir DIRport = 9101 QueryFile = "/etc/bacula/scripts/query.sql" WorkingDirectory = "/var/lib/bacula" PidDirectory = "/var/run/bacula" Maximum Concurrent Jobs = 1

Re: [Bacula-users] Bacula tapes marked FULL too early - VolBytes too low

2012-11-28 Thread Andre Rossouw
pected amount of data again. I would get your drive tested, if you have not already. -- Andre Rossouw -- Keep yourself connected to Go Parallel: VERIFY Test and improve your parallel project with help fr

Re: [Bacula-users] Backup of remote PC "hangs" but no error message

2012-06-28 Thread Andre Rossouw
Dumb question: are all the devices able to find each other on the network, and is bacula bound to the correct IP? Not sure if that makes sense, but I've had issues where the FD or SD binds to local 127.0.1.1 address instead of the eth0 IP. Which was always an oversight on my part when configuri

Re: [Bacula-users] Only one job running at any given time

2012-06-04 Thread Andre Rossouw
ce in the bacula-dir.conf and also in the Storage resource in > bacula-sd.conf, and the FileDaemon resource in the bacula-fd.conf. > I'm running out of ideas and places as I've been adding in a new > location when one does not work. Can someone point me in a direction? And have yo

Re: [Bacula-users] Tandberg LTO-3 only writing ~200GB

2012-04-19 Thread Andre Rossouw
> > Could there be any other reason you may think of (possibly outside of > > bacula) that would cause a drive to think it's written more than it has, > > or for the job to start at the wrong point on the tape? > > LTO media does not work that way. To write from beginning to end it > does multiple

Re: [Bacula-users] Tandberg LTO-3 only writing ~200GB

2012-04-19 Thread Andre Rossouw
u may think of (possibly outside of bacula) that would cause a drive to think it's written more than it has, or for the job to start at the wrong point on the tape? > -John > > On Thu, Apr 19, 2012 at 1:07 AM, Andre Rossouw > wrote: > I'm hoping s

Re: [Bacula-users] Tandberg LTO-3 only writing ~200GB

2012-04-18 Thread Andre Rossouw
ialWrite: -00-00 00:00:00 ScratchPoolId: 0 RecyclePoolId: 0 Comment: NULL On Wed, 2012-04-18 at 22:19 +0200, Andre Rossouw wrote: > Thanks for the replies. I still have 2 questions: > > On Wed, 2012-04-18 at 19:37 +0200, ganiuszka wrote: > > 2012/4/18 Andre R

Re: [Bacula-users] Tandberg LTO-3 only writing ~200GB

2012-04-18 Thread Andre Rossouw
Thanks for the replies. I still have 2 questions: On Wed, 2012-04-18 at 19:37 +0200, ganiuszka wrote: > 2012/4/18 Andre Rossouw : > > Hello. > > > > I have a system running Ubuntu 10.04 with Bacula 5.0.1. and a SCSI > > Tandberg LTO-3 HH drive. It has been running with

[Bacula-users] Tandberg LTO-3 only writing ~200GB

2012-04-18 Thread Andre Rossouw
manuals/en/problems/problems/ and so far the drive seems ok. Drive speed tests report normal, and other operations seem normal. Can anybody share some information that will help me write more than ~200GB data to media? -- Andre Rossouw