Re: [Bacula-users] Bacula Client Behind NAT

2022-10-17 Thread Bill Arlofski via Bacula-users
On 10/17/22 13:14, Rodrigo Reimberg via Bacula-users wrote: > Telnet from DIR to FD on port 9102 not ok, I’m using ConnectToDirector parameter. Hello Rodrigo, Of course this will not work. The client is behind NAT, and the Director cannot connect to it on port 9102 (or any other port :). A

Re: [Bacula-users] Bacula Client Behind NAT

2022-10-17 Thread Rodrigo Reimberg via Bacula-users
Telnet from FD to SD on port 9103 -> it’s OK Telnet from FD to DIR on port 9101 -> It’s OK Telnet from DIR to FD on port 9102 not ok, I’m using ConnectToDirector parameter. From: Josh Fisher via Bacula-users Sent: segunda-feira, 17 de outubro de 2022 09:01 To: bacula-user

Re: [Bacula-users] VirtualFull, file storage, rsnapshot-like...

2022-10-17 Thread Josh Fisher via Bacula-users
On 10/16/22 12:21, Marco Gaiarin wrote: Mandi! Radosław Korzeniewski In chel di` si favelave... ... I do not understand your requirements. What is an "initial backup" you want to make? Are you referring to the first Full backup which has to be executed on the client? Exactly. VirtualFull c

Re: [Bacula-users] Bacula Client Behind NAT

2022-10-17 Thread Josh Fisher via Bacula-users
On 10/16/22 11:44, Rodrigo Reimberg via Bacula-users wrote: Hello, Can someone help me? I did the configuration of the client behind nat. The client is communicating with the director as there is no error in the "working" directory. When I access bconsole in the director and run the statu