Hi,
After more testing done today, this looks like a mtx bug: issuing command "mtx
load 1 0" correctly loads tape from the changer slot 1 into the first tape
drive. However, "mtx status" then shows this tape drive as loaded with slot 45
instead (but also correctly lists slot 1 as empty):
# mtx
On Tuesday, June 27, 2017 5:42:10 PM EDT Ivan Adzhubey wrote:
> The
> problem I suspect is with the extra I/O slot which this model has, in
> addition to normal slots in the mounted magazines. Mtx command correctly
> reports all magazine slots plus the I/O slot (separately). However, Bacula
> direc
Hi,
I have configured Bacula for our Qualstar TLS-8466 autochanger and everything
seems be working fine except for the weird errors in slot numbering. The
problem I suspect is with the extra I/O slot which this model has, in addition
to normal slots in the mounted magazines. Mtx command correct