Re: [Bacula-users] Autochanger incorrectly assigning first slot number

2017-06-27 Thread Ivan Adzhubey
Hi, After more testing done today, this looks like a mtx bug: issuing command "mtx load 1 0" correctly loads tape from the changer slot 1 into the first tape drive. However, "mtx status" then shows this tape drive as loaded with slot 45 instead (but also correctly lists slot 1 as empty): # mtx

Re: [Bacula-users] Autochanger incorrectly assigning first slot number

2017-06-27 Thread Ivan Adzhubey
On Tuesday, June 27, 2017 5:42:10 PM EDT Ivan Adzhubey wrote: > The > problem I suspect is with the extra I/O slot which this model has, in > addition to normal slots in the mounted magazines. Mtx command correctly > reports all magazine slots plus the I/O slot (separately). However, Bacula > direc

[Bacula-users] Autochanger incorrectly assigning first slot number

2017-06-27 Thread Ivan Adzhubey
Hi, I have configured Bacula for our Qualstar TLS-8466 autochanger and everything seems be working fine except for the weird errors in slot numbering. The problem I suspect is with the extra I/O slot which this model has, in addition to normal slots in the mounted magazines. Mtx command correct