Re: [Bacula-users] Configuring autochanger with SAS LTO-5 drives

2017-06-05 Thread Alan Brown
On 05/06/17 11:57, Cejka Rudolf wrote: Hi, I do use 16 GB. Every EOF mark means around 3 seconds delay. So if you have over 200 files on the tape using 8 GB, it is around 10 minutes extra per tape. Hi, small fix. It seems that it is even around 5-6 seconds delay resulting in extra 20 minutes p

Re: [Bacula-users] Configuring autochanger with SAS LTO-5 drives

2017-06-05 Thread Cejka Rudolf
Cejka Rudolf wrote (2017/06/02): > Ivan Adzhubey wrote (2017/06/01): > > b) What is the effect of MaximumFileSize option and what would be its > > optimal > > value for my IBM LTO-5 SAS drives? I have used 8GB value found in one of > > the > > list posts, while the documentation suggests 2GB fo