Hello,
Sorry you are having problems. You did a perfect job of supplying
the right information :-)
It looks like for some reason you did not have tape EPW681L3 in the
autochanger the last time you did an "update slots barcodes" so
the slot
...Curiously, I marked "EPW681L3" as "Full" status from bconsole, and it
change the next tape to "Recycle" Status. Why is Bacula setting tapes to
"Recycle" status? It never used to do that. The again, I was never on level
7.0.5 before either...
| 17 | EPW681L3 | Full | 1 |
Hello,
We are running Bacula 7.0.5 on CentOS 7.0. This weekend, one of our full
stores blocked waiting on a tape. However I was trying to enjoy the nice
Chicago weather and trying not to think about work, so needless to say our
backup failed.
Starngely, we have another tape that SHOULD be availabl
Hello,
I noticed in the documentation that to use a Bacula plugin with Accurate
backup, the plugin must be compatible with this type of backup. Anyone
know if the alldrives Windows plugin is compatible or not with Accurate
backup?
>From the docs:
"Accurate must not be enabled when backing up wit
Why Bareos/Bacula write label while I've already labeled it?
"Wrote label to prelabeled Volume "Volume01" on device "Device01" (/dev/nst0)"
+--
|This was sent by jalil1...@gmail.com via Backup Central.
|Forward SPAM to ab...@back