HI
I try configure my chan_ss7 ,everything working fine with on one DPC on
one signaling link. But my operator was give mi two DPC on one signal
link and second signal i redundant.
My confiuration is Sangoma 8xE1. on first 6xE1 I must use DPC 3434 and
on 7 and 8 E1 a I need use DPC 13442
Bu
OK I was set correct this and it's now work ok.
I was must add another linkset ,
change MPC1 and MPC2 as combined,
Assign last two E1 to MPC2 linkest
set in link 7 and 8 spc as 3434(my sp central)
and
On host add MPC2:13422 (my second DPC from tele).
Thanks for post:
http://markmail.org/mes
Hi
Below my working ss7.conf
[linkset-MSC1]
enabled => yes
enable_st => no
use_connect => yes
hunting_policy => seq_htl
;hunting_policy => even_mru
subservice => auto
context => incoming
language => pl
t35 => 15000,timeout
*combined => mated-pair *
[linkset-MSC2]
enabled => yes
enable_st => no
Hi
I have another problem with Chan_ss7.
Sample:Client A (sip client ) calling
to---SS7(cic31) -->SS7(cic1)
> (sip client) B .
If client A Hangup is everything fine is Cause 16 and voice is end
correct but when client