his side everthing is up
and running.
According to the information i gave above, can anybody give me a hint,
where to look for an error.
I further information are required please send me an email and i will
try to provide them.
Thanks in advance.
Regards,
--
Tobias Wolf
Leiter Software
. You need to get that fixed first.
>>
>> Matthew Fredrickson
>>
>>> Rgrds
>>> Markus
>>>
>>>
>>> Tobias Wolf wrote:
>>>> Hi all,
>>>>
>>>> we have used Asterisk with Standard PRI E1 Connection for some
Tobias Wolf schrieb:
> Thanks for the Input ... I will try to get this red alarm fixed.
>
> Vernier Umali schrieb:
>> Maybe the cable is connected to the wrong port?
>>
Ok, i have verified to which port the cable is connected. It is the
lower port. Furthermore they told me,
userspace
[1638950.064463] Completed startup!
Could the jumper setting on the card create an issue with SS7 connection
to an Erricson AXE ?
Regards,
--
Tobias Wolf
Leiter Softwareentwicklung / Kommunikationslösungen
Evision GmbH
Wittekindstr. 105
44139 Dortmund
Tel: +49 (0
the card, right ?
Regards,
--
Tobias Wolf
Leiter Softwareentwicklung / Kommunikationslösungen
Evision GmbH
Wittekindstr. 105
44139 Dortmund
Tel: +49 (0)231 - 47790 307
Fax: +49 (0)231 - 47790 500
http://www.evision.de
This electronic mail transmission and any acc
Hi,
Vernier Umali schrieb:
> It appears that way.
>
We have corrected the jumpers to E1 mode and now the red alarm is gone.
We are now moving to the next step ...
I keep you informed of our progress ;)
Regards,
--
Tobias Wolf
Leiter Softwareentwicklung / Kommunikationslö
FSN: 127 FIB 1
BSN: 96 BIB 1
>[0] MSU
[ e0 ff 09 ]
Network Indicator: 2 Priority: 0 User Part: ISUP
[ 85 ]
OPC 7430 DPC 7420 SLS 3
[ fc 9c 41 37 ]
CIC: 3
[ 03 00 ]
Message Type: RLC
[ 10 ]
==
Hi,
Matthew Fredrickson schrieb:
> Tobias Wolf wrote:
>> Hi,
>>
>> here is the proposed follow-up:
>>
>> We can now terminate calls over SS7 at our asterisk.
>>
>> The main reason for us to switch to SS7 was the availability to see the
>> calleri
this possible with libss7? Should we have two or one
pointcode for the asterisk server?
I hope i made myself clear. If i slipped some important information
don't hesitate to ask me, i will gladly provide further information.
Kind Regards,
--
Tobias Wolf
Leiter Softwareentwic
can think of, that the SS7 switch can give me this
functionality. Do you have any information on this ?
Thanks for you help ;)
Kind Regards,
Tobias Wolf
___
--Bandwidth and Colocation Provided by http://www.api-digital.com--
asterisk-ss7 mailing list
Matthew Fredrickson schrieb:
> Kristian Nielsen wrote:
>> Tobias Wolf <[EMAIL PROTECTED]> writes:
>>
>> I believe you can do this with chan_ss7, setting up two boxes as a
>> cluster, though I think you would set up both boxes with the same point
>> code.
Matthew Fredrickson schrieb:
>
> Besides getting everything ready so that we pass all interconnection
> tests, it is the next highest priority.
>
Wow, this sounds great.
good luck to you all and keep up the good work. it awesome ;)
tobias
___
--Ban
12 matches
Mail list logo