Re: [asterisk-ss7] chan_ss7 - T22 timeout (No 'circuit group reset acknowledge' from peer)

2008-07-20 Thread Anton
BTW, i have no experience with SIEMENS cases, but Erricson, Huawei and ZTE working. On Monday 21 July 2008 11:34, Low Yu Siang wrote: > I am connecting to a Siemens switch. I waited for hours, > T23 timer are also appearing. Currently I see in the > chan_ss7 code that the timeout value is set at

Re: [asterisk-ss7] chan_ss7 - T22 timeout (No 'circuit group reset acknowledge' from peer)

2008-07-20 Thread Anton
Try adjusting too, but in my case i did not need to modify it. Actually I see that message appearing several times, and after 3-4 timeouts finally receiving GRA On Monday 21 July 2008 11:34, Low Yu Siang wrote: > I am connecting to a Siemens switch. I waited for hours, > T23 timer are also appea

Re: [asterisk-ss7] chan_ss7 - T22 timeout (No 'circuit group reset acknowledge' from peer)

2008-07-20 Thread Low Yu Siang
I am connecting to a Siemens switch. I waited for hours, T23 timer are also appearing. Currently I see in the chan_ss7 code that the timeout value is set at 30 seconds, are you suggesting that I should modify the code so that it is >120 seconds? Thanks. Yu Siang --- On Mon, 21/7/08, Anton <[E

Re: [asterisk-ss7] chan_ss7 - T22 timeout (No 'circuit group reset acknowledge' from peer)

2008-07-20 Thread Anton
I have similar issue with connecting to ZTE and HUAWEI switches. GRA comes not imediatelly, but after 1-2 minutes. Maybe you have the same issue. Did you wait long enough? On Saturday 19 July 2008 19:39, Low Yu Siang wrote: > Hi all, > > Thanks to the generous help from Mr. Pawel Ratajewski, I >