Wrong. It can!
Eurodis Schweiz AG
Data Division
Timo Kilchenmann
Systems Engineer
---
Timo Kilchenmann E-Mail [EMAIL PROTECTED]
Eurodis Schweiz AG Phone +41 1 843 34 91 (direct)
Bahnstrasse 58/60or +41 1 843 32 32
CH-8105
I had similar problems with TSM on AIX with 3590 drives. I asked IBM to
apply the latest drive firmware. This helped.
I suggest you check with IBM if the latest firmware is installed on the
drives, and if not ask IBM to apply new firmware.
Eurodis Schweiz AG
Data Division
Timo Kilchenmann
=> *SM-Server ==> drive ==> tapevolume because this
will take a lot of time!
In case no. 1 would we have to mess around with the *SM DB?
Any thoughts about this are very much appreciated!
Eurodis Schweiz AG
Data Division
Timo Kilche
Kilchenmann
Systems Engineer
---
Timo Kilchenmann E-Mail [EMAIL PROTECTED]
Eurodis Schweiz AG Phone +41 1 843 34 91 (direct)
Bahnstrasse 58/60or +41 1 843 32 32
CH-8105 Regensdorf Telefax +41 1 843 34 24
Switzerland
Dear all,
Restoring the Data/Directories on a Windows NT 4.0 system does not restore
the "shares". Is this the expected behavior or a bug?
Any ideas or suggestions?
Eurodis Schweiz AG
Data Division
Timo Kilchenmann
System
appreciated!!!
Eurodis Schweiz AG
Data Division
Timo Kilchenmann
Systems Engineer
---
Timo Kilchenmann E-Mail [EMAIL PROTECTED]
Eurodis Schweiz AG Phone +41 1 843 34 91 (direct)
Bahnstrasse 58/60or +41 1 843 32 32
CH-8105 Regensdorf
appreciated.
Eurodis Schweiz AG
Data Division
Timo Kilchenmann
Systems Engineer
---
Timo Kilchenmann E-Mail [EMAIL PROTECTED]
Eurodis Schweiz AG Phone +41 1 843 34 91 (direct)
Bahnstrasse 58/60or +41 1 843 32 32
CH-8105 Regensdorf
Via "dsmc incr" or by scheduler "incremental" action
The domain statement is as follows:
DOM ALL-LOCAL BINdery nds
Eurodis Schweiz AG
Data Division
Timo Kilchenmann
Systems Engineer
-------
Timo Kilchenmann E-Ma
ne without specifying five single schedules?
Any input appreciated. Thanks!
Eurodis Schweiz AG
Data Division
Timo Kilchenmann
Systems Engineer
---
Timo Kilchenmann E-Mail [EMAIL PROTECTED]
Eurodis Schweiz AG Phone +41 1 843 34
quot; cycle where in case of a restore you have to apply full -
incremental - incremental to become uptodate.
When there is no business need for having the database up 24x7 then I would
stick to the "old" method.
Eurodis Schweiz AG
Data Di
it use both volumes in parallel?
I cannot get a clear answer on this question out of the manuals.
Thank you very much for your help.
Eurodis Schweiz AG
Data Division
Timo Kilchenmann
Systems Engineer
---
Timo Kilchenmann E-Mail [EMAIL