: random I/O errors since repairs
Eric,
I have a 3575-L32. They key point in your original message is
that a drive was replaced. Power off library and carefully examine
all connections at library on the SCSI cable path to that drive.
Not just the one connection that was involved, maybe connection
on
]
Sent: Thursday, November 07, 2002 9:16 AM
To: [EMAIL PROTECTED]
Subject: Re: random I/O errors since repairs
Hi Burak!
No luck...
We have done the following actions:
1) I varied the drives offline in TSM
2) We removed the drives and library from SMIT (keep definition=no)
3) We installed Atape
the same errors for the same two drives...
I hope you, or someone else, has any more suggestions.
Kindest regards,
Eric van Loon
KLM Royal Dutch Airlines
-Original Message-
From: Loon, E.J. van - SPLXM
Sent: Thursday, November 07, 2002 15:04
To: [EMAIL PROTECTED]
Subject: Re: random I/O err
Airlines
-Original Message-
From: Loon, E.J. van - SPLXM
Sent: Thursday, November 07, 2002 15:04
To: [EMAIL PROTECTED]
Subject: Re: random I/O errors since repairs
Hi Burak!
I'm currently running 7.0.7.0. I will upgrade it right away, I will let you
know the result.
THANKS!!!
Ki
2002 14:47
To: [EMAIL PROTECTED]
Subject: Re: random I/O errors since repairs
upgrade to the latest Atape driver. this is what get as a recommendation
from
IBM.
regards,
the latest version is 7.1.5.0
check yours with:
lslpp -l |grep Atape
Burak Demircan
CEO / ITT
MERCEDES-BENZ TUR
: random I/O errors since repairs
Hi *SM-ers!
We have a 3575-L32 library. About a week ago the library was unavailable due
to a broken drive (drive 1 which is also the library control path). The
power board was replaced and everything looked fine afterwards.
Since then, every now and then drives
Hi *SM-ers!
We have a 3575-L32 library. About a week ago the library was unavailable due
to a broken drive (drive 1 which is also the library control path). The
power board was replaced and everything looked fine afterwards.
Since then, every now and then drives go offline after the following error