We've found E304 to be very good. We had many failed mounts until we applied
E304.
-
Tom
> -Original Message-
> From: Debbie Lane [mailto:[EMAIL PROTECTED]]
> Sent: Monday, April 23, 2001 5:31 PM
> To: [EMAIL PROTECTED]
> Subject: Re: ANR8359E ANR8830E
>
>
&g
1 day to 3 years old.
Manufactures are BASF, IBM, Imation.
-Original Message-
From: [mailto:[EMAIL PROTECTED]]
Sent: Monday, April 23, 2001 12:58 PM
To: [EMAIL PROTECTED]
Subject: Re: ANR8359E ANR8830E
Debbie,
I'm experiencing the same problem in our NYC site. We had 1 failure
We are at D25D, I am going to try E304.
Thanks,
--Debbie
-Original Message-
From: Richard Sims [mailto:[EMAIL PROTECTED]]
Sent: Monday, April 23, 2001 1:02 PM
To: [EMAIL PROTECTED]
Subject: Re: ANR8359E ANR8830E
>We have been receiving an abnormal amount of ANR8359E Media Fault,
blem
with verification of Q/A"
H
"Debbie Lane" <[EMAIL PROTECTED]>@VM.MARIST.EDU> on 04/23/2001
03:27:11 PM
Please respond to "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]>
Sent by: "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]>
To: [
I've got a dozen or so 3494 Libraries with 2 to 5 3590 E1A's per silo. I
typically run into these errors a few times per week on a regular basis.
I've also had the micro code upgraded, and had *many* hardware
replacements/adjustments performed. At this point, the only thing to do
is track the erro
>We have been receiving an abnormal amount of ANR8359E Media Fault, and
>ANR8830E Excessive media failures for volume.
>Hardware has replaced the cleaning brush, tape head, and card pack.
...
>Our CE said we are current on micro code for the library and drives.
Debbie - I'd say that your drive mi
We have been receiving an abnormal amount of ANR8359E Media Fault, and
ANR8830E Excessive media failures for volume.
Hardware has replaced the cleaning brush, tape head, and card pack. ]
ADSM Server - 3.1.2.90
OS - AIX 4.3.3
Atape 6.0.4.0
atldd 4.1.5.0
Tape Library IBM 3494
Tape drive IBM 3590 E1