On Saturday 12 November 2005 15:47, William Boyer wrote:
> I just inherited a client that uses a Netapp FAS960 fibre attached to an
> AIX TSM server for the DB/LOG and stgpool space. Using the "sanlun show
> lun" command I see that there are 4 paths listed to each LUN going over
> FCS2 and FCS23. I
I just inherited a client that uses a Netapp FAS960 fibre attached to an AIX
TSM server for the DB/LOG and stgpool space. Using the
"sanlun show lun" command I see that there are 4 paths listed to each LUN going
over FCS2 and FCS23. I also appears that the
multi-pathing software was not installed
LTO "drive" cleaning is two phase: self head cleaning; and, if
thereafter warranted, cleaning tape utilization. Self cleaning
employs a brush to dislodge micro contaminants from the head. Being
an open standard, LTO affords participating vendors full flexibility
in designing internal cleaning mech
Great thankyou for your response
Ended up
Cd /dev/rmt
ls
mt -f /dev/rmt/3stc status
Had someone mounting the tape in a drive manually and went through all devices
until we found the right ones, we got there in the end.
Regards Mark
-Original Message-
From: ADSM: Dist Stor Manager