See attached text (smartctl -q noserial -x output).
Thanks,
Conrad
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.10.13-100.fc24.x86_64] (local
build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: HGST HDN726060ALE614
Firmware Version: APGNW7JH
User Capacity:6,001,175,126,016 bytes [6.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate:7200 rpm
Form Factor: 3.5 inches
Device is:Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:Sun May 7 17:31:53 2017 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Disabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection:( 113) seconds.
Offline data collection
capabilities:(0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities:(0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability:(0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time:( 2) minutes.
Extended self-test routine
recommended polling time:( 713) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGSVALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016-0
2 Throughput_Performance P-S--- 138 138 054-101
3 Spin_Up_TimePOS--- 100 100 024-0
4 Start_Stop_Count-O--C- 100 100 000-9
5 Reallocated_Sector_Ct PO--CK 100 100 005-0
7 Seek_Error_Rate PO-R-- 100 100 067-0
8 Seek_Time_Performance P-S--- 140 140 020-15
9 Power_On_Hours -O--C- 100 100 000-71
10 Spin_Retry_CountPO--C- 100 100 060-0
12 Power_Cycle_Count -O--CK 100 100 000-9
192 Power-Off_Retract_Count -O--CK 100 100 000-27
193 Load_Cycle_Count-O--C- 100 100 000-27
194 Temperature_Celsius -O 171 171 000-35 (Min/Max 25/50)
196 Reallocated_Event_Count -O--CK 100 100 000-0
197 Current_Pending_Sector -O---K 100 100 000-0
198 Offline_Uncorrectable ---R-- 100 100 000-0
199 UDMA_CRC_Error_Count-O-R-- 200 200 000-0
||_ K auto-keep
|__ C event count
___ R error rate
||| S speed/performance
||_ O updated online
|__ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
AddressAccess R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics l