Dear listers,

I have defined these macros:

...
#define XTAL                       11.0592e6
#define TIME_TICK               50e-3
#define RELOAD_VALUE     -( TIME_TICK * XTAL / 12 )
...


When I use statement like this:

...
TL0  = ( unsigned char ) ( RELOAD_VALUE );
TH0  = ( unsigned char ) ( RELOAD_VALUE >> 8 );
...

I have error an warning these messages :
...
sys.c:29: error 43: invalid operand for shift operator
sys.c:29: warning 113: left & right types are
literal-float,literal-unsigned-char
sys.c:29: error 47: indirections to different types assignment
from type 'void'
to type 'sfr-volatile-unsigned-char'
...

How shoud I do the trick in SDCC?

Regards,
Fahmy



-------------------------------------------------------------------------