Hi Rolf, now hopefully the right debug information. Now after starting scanimage -A , it waits for the button information. I try different buttons (black, color) Changed before from JPEG to PDF or TIFF but scanimage waits till timeout. See the output.
regards Matthias root at matze-Satellite-C660:/usr/local/src/sane-backends-git/sane-backends# scanimage -V scanimage (sane-backends) 1.0.24git; backend version 1.0.24 root at matze-Satellite-C660:/usr/local/src/sane-backends-git/sane-backends# scanimage -A [sanei_debug] Setting debug level of pixma to 7. [pixma] pixma is compiled without pthread support. [pixma] pixma version 0.17.0 [pixma] pixma_collect_devices() found Canon PIXMA MG6200 at libusb:002:005 [pixma] sanei_bjnp_find_devices: [pixma] eth0 is IPv4 capable, sending broadcast, socket = 3 [pixma] wlan0 is IPv4 capable, sending broadcast, socket = 4 [pixma] eth0 is IPv6 capable, sending broadcast, socket = 5 [pixma] wlan0 is IPv6 capable, sending broadcast, socket = 6 [pixma] pixma_find_scanners() found 1 devices [pixma] pixma_collect_devices() found Canon PIXMA MG6200 at libusb:002:005 [pixma] sanei_bjnp_find_devices: [pixma] eth0 is IPv4 capable, sending broadcast, socket = 3 [pixma] wlan0 is IPv4 capable, sending broadcast, socket = 4 [pixma] eth0 is IPv6 capable, sending broadcast, socket = 5 [pixma] wlan0 is IPv6 capable, sending broadcast, socket = 6 [pixma] pixma_open(): Canon PIXMA MG6200 All options specific to device `pixma:04A91755_14B4F6': Scan mode: --resolution auto||75|150|300|600|1200|2400|4800dpi [75] Sets the resolution of the scanned image. --mode auto|Color|Gray|Lineart [Color] Selects the scan mode (e.g., lineart, monochrome, or color). --source Flatbed [Flatbed] Selects the scan source (such as a document-feeder). Set source before mode and resolution. Resets mode and resolution to auto values. --button-controlled[=(yes|no)] [no] When enabled, scan process will not start immediately. To proceed, press "SCAN" button (for MP150) or "COLOR" button (for other models). To cancel, press "GRAY" button. Gamma: --custom-gamma[=(auto|yes|no)] [yes] Determines whether a builtin or a custom gamma-table should be used. --gamma-table auto|0..255,... Gamma-correction table. In color mode this option equally affects the red, green, and blue channels simultaneously (i.e., it is an intensity gamma table). --gamma auto|0.299988..5 [2.2] Changes intensity of midtones Geometry: -l auto|0..216.069mm [0] Top-left x position of scan area. -t auto|0..297.011mm [0] Top-left y position of scan area. -x auto|0..216.069mm [216.069] Width of scan-area. -y auto|0..297.011mm [297.011] Height of scan-area. Buttons: --button-update Update button state [pixma] Sending time: '13/02/05 18:12' [pixma] No response yet. Timed out in 8 sec. [pixma] No response yet. Timed out in 7 sec. [pixma] No response yet. Timed out in 6 sec. [pixma] No response yet. Timed out in 5 sec. [pixma] No response yet. Timed out in 4 sec. [pixma] No response yet. Timed out in 3 sec. [pixma] No response yet. Timed out in 2 sec. [pixma] No response yet. Timed out in 1 sec. [pixma] WARNING: Error in response phase. cmd:eb80 [pixma] If the scanner hangs, reset it and/or unplug the USB cable. --button-1 <int> [0] [read-only] Button 1 --button-2 <int> [0] [read-only] Button 2 --original <int> [0] [read-only] Type of original to scan --target <int> [0] [read-only] Target operation type Extras: --threshold auto|0..100% (in steps of 1) [inactive] Select minimum-brightness to get a white point --threshold-curve auto|0..127 (in steps of 1) [inactive] Dynamic threshold curve, from light to dark, normally 50-65 [pixma] pixma_close(): Canon PIXMA MG6200 root at matze-Satellite-C660:/usr/local/src/sane-backends-git/sane-backends# -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20130205/b5394710/attachment-0001.html>