Le 21/03/2012 23:49, Peter Hackenberg a ?crit : > Hi all, > > To get my new Canon Lide 210 working I compiled sane-backends-1.0.22 > from the sources. > > At the end of the scan (with xsane 0.997 on Debian Squeeze) the scanner > bumbs into a hard stop. The following patch fixes this: > > --- genesys_devices_orig.c 2011-01-21 01:26:47.000000000 +0100 > +++ genesys_devices.c 2012-03-20 22:06:44.076961530 +0100 > @@ -1358,28 +1358,28 @@ > static Genesys_Model canon_lide_210_model = { > "canon-lide-210", /* Name */ > "Canon", /* Device vendor string */ > "LiDE 210", /* Device model name */ > GENESYS_GL124, > NULL, > > {/*2400, */ 1200, 600, /* 400,*/ 300, 150, 100, 75, 0}, /* possible > x-resolutions */ > {/*2400, */ 1200, 600, /* 400,*/ 300, 150, 100, 75, 0}, /* possible > y-resolutions */ > {16, 8, 0}, /* possible depths in gray mode */ > {16, 8, 0}, /* possible depths in color mode */ > > - SANE_FIX (3.6), /* Start of scan area in mm (x) */ > - SANE_FIX (8.5), /* Start of scan area in mm (y) */ > - SANE_FIX (213.80), /* Size of scan area in mm (x) */ > - SANE_FIX (300.0), /* Size of scan area in mm (y) */ > + SANE_FIX (1.9), /* Start of scan area in mm (x) */ > + SANE_FIX (7.9), /* Start of scan area in mm (y) */ > + SANE_FIX (217.0), /* Size of scan area in mm (x) */ > + SANE_FIX (298.0), /* Size of scan area in mm (y) */ > > SANE_FIX (0.0), /* Start of white strip in mm (y) */ > SANE_FIX (0.0), /* Start of black mark in mm (x) */ > > SANE_FIX (0.0), /* Start of scan area in TA mode in mm (x) */ > SANE_FIX (0.0), /* Start of scan area in TA mode in mm (y) */ > SANE_FIX (100.0), /* Size of scan area in TA mode in mm (x) */ > SANE_FIX (100.0), /* Size of scan area in TA mode in mm (y) */ > > SANE_FIX (0.0), /* Start of white strip in TA mode in mm (y) */ > > SANE_FIX (0.0), /* Size of scan area after paper sensor stops > > > > Two remarks on the numbers: > The excact reference corner is (with my scanner) at x = 1.7 and y = 7.7. > The sum of x-corner and x-width must not exceed 218.9, otherwise the > scanned picture gets garbled due to too less pixels per line retured. > > > > One peculiarity observed. As soon as enhancement options are enabled in > xsane (like software deskew or software crop in the extended options > window) the scanner stops at the bottom and does not return to the start > position. Well, with the next scan, it first returns to the start > position. Any ideas on that? > > > > Did anybody find out how to make e.g. "A4" the default size in the xsane > preview pane? But maybe my xsane is simply too old (0.997). > > > Best regards, > Peter > > > > > Hello,
did you test git SANE version (1.0.23git) of the genesys backend ? Regards, Stef