Le vendredi 6 janvier 2012 22:33:25 gel8440 a ?crit : > sane-devel at lists.alioth.debian.org. > greetings, > > i have run into problems getting scanner working. > > > system; > > ]$ uname -a > Linux argosyiayia.ciee.lab 2.6.18-274.12.1.el5 #1 > SMP Tue Nov 29 11:20:34 EST 2011 > i686 i686 i386 GNU/Linux > > scanner; > > Plustek OpticPro 9630p > > parallel port; > > EPP > > as normal user; > > ]# scanimage --list-devices > No scanners were identified. If you were expecting something different, > <snip> > > after changing /etc/sand.d/plustek_pp.conf from; > > [direct] > device 0x378 > > #[direct] > #device parport0 > > to; > > #[direct] > #device parport0 > > [direct] > device 0x378 > > i get; > > ]# scanimage --list-devices > device `plustek_pp:parport0' is a Plustek 9630P parallel port flatbed > scanner > > fails as user; > > ]# sane-find-scanner -p > > as user, i can not start 'xsane', i get error message that device is not > found. > > as root, i can start 'xsane'. when i try a scan, i get error; > > error during read: error during device i/o. > > > only logging is in messages; > > Jan 3 22:31:56 argosyiayia kernel: ppdev: user-space parallel port driver > > > i have been thru configs and settings so many time now that if there was a > message 'hey, you need to change...', i probably would not see it. > > i doubt that there are any list members using same scanner, but if there > are any still using or familiar with setting up a parallel port scanner > that can help, i would certainly appreciate some guidance. > > > tia. > > *please reply "plain text" only. "html text" are deleted*. thank you.
Hello, this old web page has some information for UMAX 1220P which may be of some help: http://umax1220p.sourceforge.net/trouble.html . The plustek-pp man page recommends that the port should be set in BIOS to EPP, not ECP. I also had many issues with incorrect build time kernel configuration regarding superio chipset use. I think it is worth checking. Regards, Stef