Le Wednesday 02 March 2011 12:29:23 Adrian Glaubitz, vous avez ?crit : > On Mar 2, 2011, at 12:27 PM, Adrian Glaubitz wrote: > > Hi Dimitry, > > > > On Mar 2, 2011, at 11:24 AM, ??????? ???????? wrote: > >> The scanner detects and Xsane sees it, but when you start scanning, and > >> an error in the output result is completely unreadable image. > >> > >> Scanner: HP Scan Jet 2400 > >> Console output: > >> (xsane: 4720): Pango-WARNING **: Invalid UTF-8 string passed to > >> pango_layout_set_text () -- > > > > I'm not a 100% sure but I think the ScanJet 2400 is technically identical > > to the ScanJet 2410. We had a discussion regarding this scanner a month > > ago which describes the current working status as well as a lot of debug > > information which I have collected with the USB snoop utility. > > Whoops, forgot the link to the thread in the list archives, sorry. > > Here it comes: > http://lists.alioth.debian.org/pipermail/sane-devel/2011-January/028037.ht > ml > > > Adrian > -- > sane-devel mailing list: sane-devel at lists.alioth.debian.org > http://lists.alioth.debian.org/mailman/listinfo/sane-devel > Unsubscribe: Send mail with subject "unsubscribe your_password" > to sane-devel-request at lists.alioth.debian.org Hello,
The support for the G2410/HP2400 isn't complete yet. Adrian sent me good quality USB logs. But since I'm busy reworking gl847 part to reach 4800 dpi with my LiDE 200, I haven't worked on it yet. This could be in a month or two. Meanwhile one could try to do it: the 100, 150 and 300 dpi entries in the tables contained in genesys_gl646.h have to be updated with data from the logs. I have already provided the scripts I use to process logs, and I can provide them again if someone wish it. Regards, Stef