Le jeudi 15 janvier 2009 ? 16:16 +0100, Alessandro Zummo a ?crit : > Hi, > > iirc the length can be different for each scanner model, but I might > be wrong. I've been a little busy but will try to research the issue. > Yes, the length seems to be different, using 46 as expected length doesn't work for me:
[epson2] esci_request_identity2 [epson2] e2_cmd_info_block, params len = 2, reply len = 46, buf = 0xbf96b248 [epson2] e2_send: size = 2, reply = 50 [epson2] e2_send: ESC i [epson2] buf[0] 1b . [epson2] buf[1] 69 i [epson2] e2_recv: size = 4, buf = 0xbf96afd2 Then, it locks up. If I want to use the scanner, I have to restart it (the connexion didn't end properly). If I disable the identity2 request, I can use the scanner. But an identity2 answer provides informations like the different settings supported by the scanner, no? I think this is why xsane can't get a preview (If I want to scan with xsane, I have to change the DPI, otherwise, it fails). -------------- next part -------------- A non-text attachment was scrubbed... Name: not available Type: application/pgp-signature Size: 197 bytes Desc: Ceci est une partie de message =?ISO-8859-1?Q?num=E9riquement?= =?ISO-8859-1?Q?_sign=E9e?= Url : http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20090115/331a0a0e/attachment.pgp