Dear listmembers,
a second try. I have an old Mustek SCSI-Scanner that used to work smoothly 
with my old SuSE 8.1 and kernel 2.4.

Now I have SuSE 9.3 and kernel 2.6.11, and I have some trouble.
The scanner is connected to a separate AHA 2940 card (I tested different 
ones). Termination is set to auto. Disconnecting is disabled, the scanner is 
followed by a IOMEGA ZIP SCSI-drive (which works totally flawlessly) at the 
end of this SCSI bus there is an active termination resistor.

When the scanner is "awake" I have no issues at all. However, as soon as the 
scanner falls asleep and I try to scan something I get troubles.
Attached I send a part of the contents of /var/log/messages and the output of 
the commands:

export SANE_DEBUG_DLL=128
export SANE_DEBUG_MUSTEK=128
export SANE_DEBUG_SANEI_SCSI=128
/usr/bin/scanimage -L > /var/log/scannerdebug 2>&1
/usr/bin/scanimage -T >> /var/log/scannerdebug 2>&1

The SCSI-system shows a timeout - I haven't experienced similar issues during 
years, so what might cause this.

In /etc/sane.d/mustek.conf I readily activated "option force-wait" to assure 
that the scanner is being waited for. But no success so far.

Please excuse the "bzip". The file scannerdebug.bz2 has 57kBytes when 
uncompressed, but there is a size limit on the list, so I compressed both. 
Sorry for the inconvenience.

Any suggestions / ideas are highly appreciated!
Many thanks in advance,
take care



Dieter Jurzitza

-- 
-----------------------------------------------------------

                               |
                                \
                 /\_/\           |
                | ~x~ |/-----\   /
                 \   /-       \_/
  ^^__   _        /  _  ____   /
 <??__ \- \_/     |  |/    |  |
  ||  ||         _| _|    _| _|

if you really want to see the pictures above - use some font
with constant spacing like courier! :-)
-----------------------------------------------------------
-------------- next part --------------
A non-text attachment was scrubbed...
Name: scannerdebug.bz2
Type: application/x-bzip2
Size: 6260 bytes
Desc: not available
Url : 
http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20050724/743661e1/scannerdebug.bin
-------------- next part --------------
A non-text attachment was scrubbed...
Name: scsidumpmsg.bz2
Type: application/x-bzip2
Size: 1352 bytes
Desc: not available
Url : 
http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20050724/743661e1/scsidumpmsg.bin
From henn...@meier-geinitz.de  Sun Jul 24 20:13:56 2005
From: henn...@meier-geinitz.de (Henning Meier-Geinitz)
Date: Sun Jul 24 20:15:40 2005
Subject: [sane-devel] Canon Lide 35 status (and CVS problems)
In-Reply-To: <20050724185429.gb29...@meier-geinitz.de>
References: <1122229998.16626.35.camel@stevko>
        <20050724185429.gb29...@meier-geinitz.de>
Message-ID: <20050724201356.gh29...@meier-geinitz.de>

Hi,

On Sun, Jul 24, 2005 at 08:54:29PM +0200, Henning Meier-Geinitz wrote:
> I've also mentioned the problem on #alioth.

The alioth admins were really fast and have fixed the problem now.

Bye,
  Henning

Reply via email to