I am trying to get my scanner to work with sane. I have a Canon LIDE20 usb scanner. sane-find-scanner sees the scanner but when I run scanimage -L nothing comes up. Its as if the scanner isn't there. 77 Here is what I get when I run sane-find-scanner. If someone could please point me in the right direction I would greately appreciateit.
trying libusb: <device descriptor of 0x0000/0x0000 at 001:001 (USB UHCI-alt Root Hub)> bLength 18 bDescriptorType 1 bcdUSB 1.00 bDeviceClass 9 bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 8 idVendor 0x0000 idProduct 0x0000 bcdDevice 0.00 iManufacturer 0 () iProduct 2 (USB UHCI-alt Root Hub) iSerialNumber 1 (d400) bNumConfigurations 1 <configuration 0> bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 () bmAttributes 64 (Self-powered) MaxPower 0 mA <interface 0> <altsetting 0> bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 bInterfaceSubClass 0 bInterfaceProtocol 0 iInterface 0 () <endpoint 0> bLength 7 bDescriptorType 5 bEndpointAddress 0x81 (in 0x01) bmAttributes 3 (interrupt) wMaxPacketSize 8 bInterval 255 ms bRefresh 0 bSynchAddress 0 <device descriptor of 0x04a9/0x220d at 001:002 (Canon CanoScan)> bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 255 bDeviceSubClass 0 bDeviceProtocol 255 bMaxPacketSize0 8 idVendor 0x04A9 idProduct 0x220D bcdDevice 1.00 iManufacturer 1 (Canon) iProduct 2 (CanoScan) iSerialNumber 0 () bNumConfigurations 1 <configuration 0> bLength 9 bDescriptorType 2 wTotalLength 39 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 () bmAttributes 160 (Remote Wakeup) MaxPower 500 mA <interface 0> <altsetting 0> bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 3 bInterfaceClass 255 bInterfaceSubClass 0 bInterfaceProtocol 255 iInterface 0 () <endpoint 0> bLength 7 bDescriptorType 5 bEndpointAddress 0x81 (in 0x01) bmAttributes 3 (interrupt) wMaxPacketSize 1 bInterval 16 ms bRefresh 0 bSynchAddress 0 <endpoint 1> bLength 7 bDescriptorType 5 bEndpointAddress 0x82 (in 0x02) bmAttributes 2 (bulk) wMaxPacketSize 64 bInterval 0 ms bRefresh 0 bSynchAddress 0 <endpoint 2> bLength 7 bDescriptorType 5 bEndpointAddress 0x03 (out 0x03) bmAttributes 2 (bulk) wMaxPacketSize 64 bInterval 0 ms bRefresh 0 bSynchAddress 0 <trying to find out which USB chip is used> checking for GT-6801 ... this is not a GT-6801 (bDeviceSubClass = 0x0) checking for GT-6816 ... this is not a GT-6816 (bDeviceClass = 255, bInterfaceClass = 255) checking for MA-1017 ... this is not a MA-1017 (bDeviceClass = 255, bInterfaceClass = 255) checking for MA-1015 ... this is not a MA-1015 (bcdUSB = 0x110) checking for MA-1509 ... this is not a MA-1509 (bDeviceSubClass = 0x0) checking for LM983[1,2,3] ... Couldn't claim interface: could not claim interface 0: Device or resource busy <This USB chip looks like a LM983x?> found USB scanner (vendor=0x04a9 [Canon], product=0x220d [CanoScan], chip=LM983x?) at libusb:001:002 <device descriptor of 0x046d/0xc20c at 001:003 (Logitech WingMan Precision USB)>bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 0 bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 8 idVendor 0x046D idProduct 0xC20C bcdDevice 1.03 iManufacturer 1 (Logitech) iProduct 2 (WingMan Precision USB) iSerialNumber 0 () bNumConfigurations 1 <configuration 0> bLength 9 bDescriptorType 2 wTotalLength 34 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 () bmAttributes 128 () MaxPower 30 mA <interface 0> <altsetting 0> bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 bInterfaceSubClass 0 bInterfaceProtocol 0 iInterface 0 () <endpoint 0> bLength 7 bDescriptorType 5 bEndpointAddress 0x81 (in 0x01) bmAttributes 3 (interrupt) wMaxPacketSize 3 bInterval 10 ms bRefresh 0 bSynchAddress 0 # Your USB scanner was (probably) detected. It may or may not be supported by # SANE. Try scanimage -L and read the backend's manpage. -- --------------------------------------------------------------- Philip V. Neves Email: phi...@digitalinfinity.biz Phone: (250)372-8536 pne...@telus.net --------------------------------------------------------------- Nearly every man who develops an idea works at it up to the point where it looks impossible, and then gets discouraged. that's not the place to become discouraged. Thomas Alva Edison.