Till friday I had much to do. So my answere comes today as I continued to test.
Am 03.04.03, 18:27 +0200 schrieb Oliver Rauch: > May be you have a problem with the lamp or the calibration. > > What results when you do: > > - preview #1 > - scan #1 > - preview #2 > - scan #2 > > (always the same areas and images). The differences between preview and scan are constant over time. As the result of some testing I could see, equal to positiv and all negative scanning combinations, the changes of colors came while using other settings than full range from the filmtype selector. The more the film type preadjusts the image the more will be color changes between preview and final scan visible. For Negatives it is better visible than with postives. > Oliver > -- Kai-Uwe