On Fri, 9 May 2003, Rene Rebe wrote: > Hi, >=20 > On: Wed, 7 May 2003 17:06:19 -0400 (EDT), > "m. allan noah" <an...@pfeiffer.edu> wrote: > > On Tue, 1 Apr 2003, m. allan noah wrote: > >=20 > > > > * Check if sp15c backend (Fujitsu ScanPartner 15C) can be include= d in > > > > fujitsu or avision backends. > > >=20 > >=20 > > i put out a call for this scanner on this list, and got no responses. t= his=20 > > morning, i actually found one of these in a box where i work. i have sp= ent=20 > > a few minutes here playing with it, and with a tiny patch to avision.c,= it=20 > > appears to work as well under the avision backend as it does under the= =20 > > sp15 one. i will do some more tests for discrepancies, and send patches= to=20 > > rene (avision maint). > >=20 > > this scanner is different enough in protocol from non-scanpartner fujit= su=20 > > scanners that it makes no sense to expand fujitsu backend to support it= =2E=20 > > therefore, i will also send patch to oliver (fujitsu maint) to remove a= ll=20 > > mention of sp15 from fujitsu backend. >=20 > That is really nice! I'll merge the tiny ADF check improvement > soon. What state should I give the scanner in the .desc? beta or > stable? >=20
well, i have spent some time looking, and i would call the fujitsu sp300,= =20 600, jr, and 15c all beta. i say this because i find 3 major differences between the avision backend= =20 and the sp15c one. 1. avision backend does not support 4 bit grayscale 2. the fcpa scanpartner scanners have more limited possible resolutions 3. the avision driver does not support independent x/y resolution output using sp15c backend: Options specific to device `sp15c': Scan Mode: --source ADF|FB [ADF] Selects the scan source (such as a document-feeder). --mode Lineart|Halftone|4-bit Gray|8-bit Gray|Color [Lineart] Selects the scan mode (e.g., lineart,monochrome, or color). --resolution 0|60|75|80|100|120|150|200|240|300|600dpi [200] Sets the horizontal resolution of the scanned image. --y-resolution 0|60|75|80|100|120|150|200|240|300|600dpi [200] Sets the vertical resolution of the scanned image. Geometry: -l 0..216mm (in steps of 1.52588e-05) [0] Top-left x position of scan area. -t 0..356mm (in steps of 1.52588e-05) [0] Top-left y position of scan area. -x 0..216mm (in steps of 1.52588e-05) [215.47] Width of scan-area. -y 0..356mm (in steps of 1.52588e-05) [279.364] Height of scan-area. Enhancement: --threshold 0..255 (in steps of 4) [128] Select minimum-brightness to get a white point Advanced: output using avision: Options specific to device `avision': Scan mode: --mode Line Art|Dithered|Gray|Color [Color] Selects the scan mode (e.g., lineart,monochrome, or color). --resolution 50..300dpi (in steps of 10) [300] Sets the resolution of the scanned image. --speed 0..4 (in steps of 1) [inactive] Determines the speed at which the scan proceeds. --preview[=3D(yes|no)] [no] Request a preview-quality scan. Geometry: -l 0..215mm [0] Top-left x position of scan area. -t 0..295mm [0] Top-left y position of scan area. -x 0..215mm [215] Width of scan-area. -y 0..295mm [295] Height of scan-area. Enhancement: --brightness -100..100% (in steps of 1) [0] Controls the brightness of the acquired image. --contrast -100..100% (in steps of 1) [0] Controls the contrast of the acquired image. --quality-scan[=3D(yes|no)] [yes] Turn on quality scanning (slower but better). --quality-cal[=3D(yes|no)] [yes] Do a quality white-calibration --transparency[=3D(yes|no)] [inactive] Switch transparency mode on. Which mainly switches the scanner=20 lamp off. (Hint: This can also be used to switch the scanner lamp off=20 when you don't use the scanner in the next time. Simply enable this=20 option and perform a preview.) --adf[=3D(yes|no)] [no] This option enables the Automatic-Docuement-Feeder of the scanner. This allows you to scan multiple pages manually or automatically. --gamma-table 0..255,... Gamma-correction table. In color mode this option equally affects= =20 the red, green, and blue channels simultaneously (i.e., it is an=20 intensity gamma table). --red-gamma-table 0..255,... Gamma-correction table for the red band. --green-gamma-table 0..255,... Gamma-correction table for the green band. --blue-gamma-table 0..255,... Gamma-correction table for the blue band. --frame 0..0 [inactive] Selects the number of the frame to scan i have not tried all the options of the avision backend to see if they=20 work yet. > Could you send me the log from: > SANE_DEBUG_AVISION=3D7 scanimage -L it will come to you alone in sep. email. allan >=20 > Thanks! >=20 > > allan >=20 > - Ren=E9 >=20 > -- =20 > Ren=E9 Rebe - Europe/Germany/Berlin > e-mail: r...@rocklinux.org, rene.r...@gmx.net > web: http://www.rocklinux.org/people/rene http://gsmp.tfh-berlin.de/= rene/ >=20 > Anyone sending unwanted advertising e-mail to this address will be > charged $25 for network traffic and computing time. By extracting my > address from this message or its header, you agree to these terms. > _______________________________________________ > Sane-devel mailing list > sane-de...@www.mostang.com > http://www.mostang.com/mailman/listinfo/sane-devel >=20 --=20 "so don't tell us it can't be done, putting down what you don't know. money isn't our god, integrity will free our souls" - Max Cavalera