Hi there, After some hours trying the new Epson-KAWA frontend I think this should NOT be called a 'SANE frontend'; it comes with it's own backend called 'epson' which looks incompatible to the epson backend currently in SANE(CVS). First, I installed SANE from sources below /usr/local and the Kawa thing from the RPM, giving me 'can't send command to scanner' messages due to a) a Bug in the SANE epson.c (Patch enclosed) b) different option names used in epson-KAWA and epson-SANE (e.g. "User Defined (Gamma 1.8)" [Kawa] vs. "User Defined" [Sane] for one of the Gamma correction options). BTW, there is a misleading comment in sanei/sanei_constrain_value.c: the code for STRING_LIST doesn't work like the comment describes (it will match ALWAYS exact strings, so making the ugly copy of the list value back to the parameter useless). After discovering my install problem (iscan+backend in /usr, SANE in /usr/local) I installed iscan+backend also in /usr/local. Now iscan works, but I can't get xsane to display previews. I think it would be useful to state on the SANE pages that iscan requires its own [incompatible] backend. Will there be a merge between Kawa and sane-epson ? Regards, Thomas Ref: http://www.epkowa.co.jp/english/index_e.html -- Bergbilder: http://www.timeware.at/wet --=-khV39RcL4JVwkvuD8pK/ Content-Disposition: inline; filename=epson.diff Content-Transfer-Encoding: quoted-printable Content-Type: text/plain; charset=ISO-8859-1 Index: epson.c =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D= =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D= =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D RCS file: /cvsroot/external/sane/sane-backends/backend/epson.c,v retrieving revision 1.26 diff -c -r1.26 epson.c *** epson.c 2002/01/19 14:07:25 1.26 --- epson.c 2002/03/17 18:30:27 *************** *** 1401,1423 **** * Send the "initialize scanner" command to the device and reset it. * */ -=20 static SANE_Status reset ( Epson_Scanner * s) { SANE_Status status; u_char param[2]; =20 if( ! s->hw->cmd->initialize_scanner) return SANE_STATUS_GOOD; =20 param[0] =3D ESC; param[1] =3D s->hw->cmd->initialize_scanner; =20 send (s, param, 2, &status); status =3D expect_ack( s); return status; } -=20 -=20 /* * close_scanner() * --- 1401,1434 ---- * Send the "initialize scanner" command to the device and reset it. * */ static SANE_Status reset ( Epson_Scanner * s) { SANE_Status status; u_char param[2]; + int need_open =3D 0; =20 if( ! s->hw->cmd->initialize_scanner) return SANE_STATUS_GOOD; =20 + need_open =3D s->fd < 0; +=20 + if (need_open) { + DBG(5, "reset calling open_scanner\n"); + if ((status =3D open_scanner(s)) !=3D SANE_STATUS_GOOD) + return status; + } +=20 param[0] =3D ESC; param[1] =3D s->hw->cmd->initialize_scanner; =20 send (s, param, 2, &status); status =3D expect_ack( s); +=20 + if (need_open) { + close_scanner(s); + s->fd =3D -1; + } return status; } /* * close_scanner() * --=-khV39RcL4JVwkvuD8pK/--