It's an error reported by the OS (upon an API call made by Servers Alive)
1707 The network address is invalid. RPC_S_INVALID_NET_ADDR
Do you get the 1707 for all service checks on that server?
>From the error I would think it has something to do with the "hostname"
used. Try the IP or the Netbios name, not the FQN (host.domain.com)
dirk.
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
Behalf Of Ramsey, Craig
Sent: Thu Apr 03 3:03 PM
To: '[EMAIL PROTECTED]'
Subject: [SA-list] OpenSCManager Error
I have a monitor on my exchange server monitoring the exchange public is
store service. It correctly reported the 'down' notification , but now it
is up but SA still reports it down. I looked into the configuration of the
check, and when I go to the checks tab, and click on NT Service button to
list the services, it gives an error: OpenSCManager failed; Error=1707. I
have tried to rebuild the check but it does the same thing.
Any ideas?