On  3-07-2015, at 23h 07'34", Costin Gușă wrote about "Re: [rlug] SMART error 
(Usage) detected"
> On Friday, July 3, 2015, Costin Gușă <it.cgusa+lug...@gmail.com> wrote:
> >
> >
> >  [...]
> > Hdd-urile au si un interval de functionare dat de producator, poti sa ni-l
> > arati cu smartctl -x (versiunile mai noi au acest parametru; pentru ca ai
> > dat deja -a poti sa faci acum doar un -l scttemp si -l scttemphist)?
> > [...]
> >
> 
> De fapt e suficient -l scttempsts pentru verificarea intervalului (produce
> mai putin output fata de celelalti doi parametri)



# smartctl -l scttempsts /dev/sda
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
SCT Status Version:                  2
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                 55 Celsius
Power Cycle Max Temperature:         55 Celsius
Lifetime    Max Temperature:         55 Celsius

# smartctl -l scttempsts /dev/sdb
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
SCT Status Version:                  3
SCT Version (vendor specific):       522 (0x020a)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    64 Celsius
Power Cycle Min/Max Temperature:     26/64 Celsius
Lifetime    Min/Max Temperature:     21/64 Celsius
Under/Over Temperature Limit Count:   0/23

# smartctl -l scttempsts /dev/sdc
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
SCT Status Version:                  3
SCT Version (vendor specific):       522 (0x020a)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    62 Celsius
Power Cycle Min/Max Temperature:     27/63 Celsius
Lifetime    Min/Max Temperature:     17/63 Celsius
Under/Over Temperature Limit Count:   0/1489