Wrenches,

After 10+ years of MLPE (microinverters/optimizers) gaining traction in the
industry, I have noticed one stubborn issue that somehow still haunts us. I
think we as installers have all been there at some point: laying down the
final module in an array, high fives all around, time to look at the
close-out checklist that our pesky operations manager handed to us on our
way out the door, and then realizing that we forgot to peel off the MLPE
serial number stickers (or otherwise record them) in order to make a map...

Even when installers forget to record just one serial number, retrieving it
can be difficult and time-consuming. Raise your hand if you've ever
attached your cell phone/camera to an extendable pole and slid it under the
array in hopes of catching that one forgotten label!

In this age of smart devices, I anxiously await the day when MLPE will be
able to map themselves. But until that day comes, I am wondering if anyone
has developed or knows of a tried-and-true foolproof method for capturing
MLPE serial numbers?

--