Hello Wrenches, You may be aware of this but the -92R firmware supposedly has addressed the arc fault issue for the US-40 inverters. See here for the download: https://www.sma-america.com/service-support/downloads.html It fixed an arc fault issue for me yesterday at least. Bring a thumb drive, the update process took about an hour to perform.
On Tue, Sep 3, 2019 at 10:40 AM Dave Angelini Offgrid Solar < offgridso...@sti.net> wrote: > Same up here in the southern sierra. I get calls from ABB and a few from > SMA to look at systems that people far away installed and as a local 3rd > party it can save some money. Whatever they quote me I triple the price. > 1/3 up front and the rest when it is done. ABB is really slow with payment. > I think they sold their inverter business? Sunpower is a great panel but > they have had some bad runs. Probably why there are so many new/used panels > on the secondary market. They are great for Offgrid ground arrays and no > AFD. > > On Tue, 3 Sep 2019 09:52:19 -0400, Dave Tedeyan <dtede...@taitem.com> > wrote: > > Chris, > Sunpower has taken some responsibility on some of our older Sunpower > systems that are arc faulting. We tell them that a system is arc faulting, > and then they insist on sending up a 3rd party contractor to inspect the > system and potentially install what they call "Tigo Diodes". I am still not > exactly sure what that is. It also seems to take them months to send anyone > to upstate NY, as we have a bunch of customers that have been waiting > months for the 3rd party contractor to come take a look. You likely could > only follow this route though if the system was installed by a Sunpower > dealer and you are a Sunpower dealer yourself. If the original system was > from a Sunpower dealer, you can also have the customer call Sunpower > directly. > > Cheers, > Dave > > *Dave Tedeyan, PE* > Senior Engineer | Taitem Engineering, PC > > 110 South Albany Street | Ithaca, NY 14850 > o. 607.277.1118 x121 f. 607.277.2119 > www.taitem.com > > Solar • Sustainability • Energy • Design > B-Corporation Best for the World 2018 Honoree > > On Tue, Sep 3, 2019 at 9:43 AM Chris Schaefer <ch...@solarandwindfx.com> > wrote: > >> Got called in by another peer to debug that infamous SMA error 8206 on a >> 2 year old 5kw unit. The array is roof mounted on composite shingles with >> 14 SunPower 345w modules. First time ever seeing this error on this >> project. I'd love to hear from others as to what they've found or better >> yet hear from an SMA rep as to what they suggest. Not a whole lot of detail >> in the SMA users manual. >> >> Thanks, >> Christopher >> >> Chris Schaefer's >> <http://www.solarandwindfx.com/> >> >> *Tel/Fax 585-229-2083 or Cell 585-748-1870 * >> *5115 South Hill Road ~ Canandaigua New York 14424**www.solarandwindfx.com >> <http://www.solarandwindfx.com/> ~ E-mail: ch...@solarandwindfx.com >> <ch...@solarandwindfx.com>* >> >> >> Thomas Jefferson, the author of our great Constitution, once said, >> "democracy" will cease to exist when you take away from those who are >> willing to work and give to those who would not." >> >> On Mon, Sep 2, 2019 at 12:03 PM Jerry Shafer <jerrysgarag...@gmail.com> >> wrote: >> >>> Wrenches >>> I have had chiller pump contactor along with wells, shop air compressors >>> all create enough of an arc to trigger the inverters. ABB inverters only >>> pick up off the DC but even there l had arc welders trip the inverters. >>> Jerry >>> >>> On Mon, Sep 2, 2019, 8:14 AM frenergy <frene...@psln.com> wrote: >>> >>>> Interestingly, the problems I've had with the SMA -40 AFCI faults have >>>> been on Comp roofs. When I've gone "inside" a -40 with my laptop, I'm >>>> pretty sure I've seen where you can disable it? >>>> >>>> Bill >>>> On 9/2/2019 7:12 AM, drake.chamber...@redwoodalliance.org wrote: >>>> >>>> At least with the TL-22s, the AFCI function can be turned off. You need >>>> a* Web connect speed wire module*. .I don't know if this same protocol >>>> will work for the TL 40s or not. >>>> >>>> Metal roofing can apparently be affected by radio waves and by other >>>> factors that create a disturbance that can trigger the AFCI.The TL 40 was >>>> supposed to overcome this problem. >>>> >>>> >>>> >>>> ----- Original Message ----- >>>> From: >>>> "RE-wrenches" <re-wrenches@lists.re-wrenches.org> >>>> <re-wrenches@lists.re-wrenches.org> >>>> >>>> To: >>>> "RE-wrenches" <re-wrenches@lists.re-wrenches.org> >>>> <re-wrenches@lists.re-wrenches.org> >>>> Cc: >>>> >>>> Sent: >>>> Sun, 1 Sep 2019 07:42:14 -1000 >>>> Subject: >>>> [RE-wrenches] SMA phantom arc faults >>>> >>>> >>>> Aloha all, >>>> >>>> My company has really been struggling with the SMA US-40 line of >>>> inverters and incredibly disruptive to positive customer experiences bogus >>>> arc faults. >>>> >>>> We were told by our SMA friends that a firmware update/fix was >>>> forthcoming in mid-August and we've heard nor received nothing last month. >>>> >>>> Does anyone know anything as to where they're at on this? >>>> >>>> Really frustrated.... >>>> >>>> marco >>>> >>>> >>>> _______________________________________________ >>>> List sponsored by Redwood Alliance >>>> >>>> List Address: RE-wrenches@lists.re-wrenches.org >>>> >>>> Change listserver email address & >>>> settings:http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org >>>> >>>> List-Archive: >>>> http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html >>>> >>>> List rules & etiquette:www.re-wrenches.org/etiquette.htm >>>> >>>> Check out or update participant bios:www.members.re-wrenches.org >>>> >>>> -- >>>> Feather River Solar Electric >>>> Bill Battagin, Owner >>>> 4291 Nelson St. >>>> Taylorsville, CA 95983 >>>> 530.284.7849 >>>> CA Lic 874049www.frenergy.net >>>> >>>> >>>> >>>> <https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=emailclient&utm_term=icon> >>>> Virus-free. >>>> www.avast.com >>>> <https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=emailclient&utm_term=link> >>>> _______________________________________________ >>>> List sponsored by Redwood Alliance >>>> >>>> List Address: RE-wrenches@lists.re-wrenches.org >>>> >>>> Change listserver email address & settings: >>>> http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org >>>> >>>> List-Archive: >>>> http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html >>>> >>>> List rules & etiquette: >>>> www.re-wrenches.org/etiquette.htm >>>> >>>> Check out or update participant bios: >>>> www.members.re-wrenches.org >>>> >>> _______________________________________________ >>> List sponsored by Redwood Alliance >>> >>> List Address: RE-wrenches@lists.re-wrenches.org >>> >>> Change listserver email address & settings: >>> http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org >>> >>> List-Archive: >>> http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html >>> >>> List rules & etiquette: >>> www.re-wrenches.org/etiquette.htm >>> >>> Check out or update participant bios: >>> www.members.re-wrenches.org >>> >> >> >> -- >> >> Chris Schaefer's >> <http:www.solarandwindfx.com> >> >> *Tel/Fax 585-229-2083 or Cell 585-748-1870 * >> *5115 South Hill Road ~ Canandaigua New York 14424**www.solarandwindfx.com >> <http://www.solarandwindfx.com> ~ E-mail: ch...@solarandwindfx.com >> <ch...@solarandwindfx.com>* >> >> >> Thomas Jefferson, the author of our great Constitution, once said, >> "democracy" will cease to exist when you take away from those who are >> willing to work and give to those who would not." >> _______________________________________________ >> List sponsored by Redwood Alliance >> >> List Address: RE-wrenches@lists.re-wrenches.org >> >> Change listserver email address & settings: >> http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org >> >> List-Archive: >> http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html >> >> List rules & etiquette: >> www.re-wrenches.org/etiquette.htm >> >> Check out or update participant bios: >> www.members.re-wrenches.org >> > -- > > > > *Dave Angelini Offgrid Solar > "we go where powerlines don't" > http://members.sti.net/offgridsolar/ <http://members.sti.net/offgridsolar/> > e-mail offgridso...@sti.net <offgridso...@sti.net> > text 209 813 0060* > > _______________________________________________ > List sponsored by Redwood Alliance > > List Address: RE-wrenches@lists.re-wrenches.org > > Change listserver email address & settings: > http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org > > List-Archive: > http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html > > List rules & etiquette: > www.re-wrenches.org/etiquette.htm > > Check out or update participant bios: > www.members.re-wrenches.org > > -- Mac Lewis *"Yo solo sé que no sé nada." -Sócrates*
_______________________________________________ List sponsored by Redwood Alliance List Address: RE-wrenches@lists.re-wrenches.org Change listserver email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out or update participant bios: www.members.re-wrenches.org