Hidenori Oishi

*************************************

 Panasonic HIT Customer Service
 TEL:1-503-365-1086
 FAX:1-503-365-6855
 Email:hitcustomerserv...@us.panasonic.com
Jim Dunphy
Group Manager of Operations
Panasonic Enterprise Solutions Company
 
T 201-392-6776
F 201-392-4379
C 201-214-7185
  
Panasonic Enterprise Solutions Company
PESCO, 5th Floor
Two Riverfront Plaza
Newark, NJ 07102  Andrew KoyaanisqatsiPresidentSolar Energy Solutions, Inc.
The BRIGHT CHOICE
Since 1987, helping you and your Portland neighbors
move towards an environmentally sustainable future.503-238-4502
www.SolarEnergyOregon.com  

    On Tuesday, August 23, 2016 11:11 AM, Kirk Herander <vtso...@icloud.com> 
wrote:
 
 

 <!--#yiv5768445133 _filtered #yiv5768445133 {font-family:Calibri;panose-1:2 15 
5 2 2 2 4 3 2 4;}#yiv5768445133 #yiv5768445133 p.yiv5768445133MsoNormal, 
#yiv5768445133 li.yiv5768445133MsoNormal, #yiv5768445133 
div.yiv5768445133MsoNormal 
{margin:0in;margin-bottom:.0001pt;font-size:11.0pt;font-family:"Calibri", 
"sans-serif";}#yiv5768445133 a:link, #yiv5768445133 
span.yiv5768445133MsoHyperlink 
{color:blue;text-decoration:underline;}#yiv5768445133 a:visited, #yiv5768445133 
span.yiv5768445133MsoHyperlinkFollowed 
{color:purple;text-decoration:underline;}#yiv5768445133 
span.yiv5768445133EmailStyle17 {font-family:"Calibri", 
"sans-serif";color:windowtext;}#yiv5768445133 .yiv5768445133MsoChpDefault 
{font-family:"Calibri", "sans-serif";} _filtered #yiv5768445133 {margin:1.0in 
1.0in 1.0in 1.0in;}#yiv5768445133 div.yiv5768445133WordSection1 {}-->Hello,I 
recently upgraded a 12 year old Sanyo HIT 167 watt (14 total) array to a 
Solaredge system while adding two strings of LG 315’s. Every time there is rain 
or heavy condensation the inverter shuts down with a ground fault error. I was 
able to isolate the error to the old Sanyo string. The Solaredge diagnostics 
estimated the fault was in the middle of the string. So we went up on the roof 
with a garden hose and trickled water on each panel individually, while 
meggaring the string at the roof combiner. Sure enough, the moisture 
infiltration was in the middle panel of the string, just as the Solaredge IRT 
test predicted. Good job Solaredge.These panels are circa 2004, so I’m 
wondering who the US contact is to ask about warranty issues. Has Panasonic 
taken over warranty claims on old Sanyo’s? I know this model isn’t made 
anymore, but maybe there is some remuneration offered. Thanks.  
_______________________________________________
List sponsored by Redwood Alliance

List Address: RE-wrenches@lists.re-wrenches.org

Change listserver email address & settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: 
http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html

List rules & etiquette:
www.re-wrenches.org/etiquette.htm

Check out or update participant bios:
www.members.re-wrenches.org



 
  
_______________________________________________
List sponsored by Redwood Alliance

List Address: RE-wrenches@lists.re-wrenches.org

Change listserver email address & settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: 
http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html

List rules & etiquette:
www.re-wrenches.org/etiquette.htm

Check out or update participant bios:
www.members.re-wrenches.org

Reply via email to