You may want to check the ac voltage with a good "true RMS" meter and see what the results are, some (most) new Freq Drives, and soft start drives may have an issue with a high RMSJerry
Sent from my Verizon Wireless 4G LTE smartphone -------- Original message -------- From: Roy Butler <r...@four-winds-energy.com> Date: 4/26/2016 4:22 AM (GMT-10:00) To: RE-wrenches <re-wrenches@lists.re-wrenches.org> Subject: Re: [RE-wrenches] Inverter/AC pump compatibility question Allan, I have several customers running the Grundfos SQE series on their modified square wave inverters. To be clear, those most recent was about 5 years ago, so perhaps there's been a design change since then. Roy Butler NABCEP Certified Solar PV InstallerĀ® NYSERDA eligible PV & wind installer Four Winds Renewable Energy, LLC 8902 Route 46, Arkport, NY 14807 607-324-9747 www.four-winds-energy.com Although no trees were killed in the sending of this message, a large number of electrons were terribly inconvenienced. On 4/25/2016 11:15 PM, Allan Sindelar wrote: Wrenches, Has anyone powered a Grundfos SQ or SQE series soft-start AC submersible pump from a modified square wave inverter? I need to run a 1/2 hp 115V AC sub on a 1990-era Heart EMS 2800-12. The customer likes his equipment so I'm not encouraging an inverter upgrade. Thank you, Allan -- <!-- /* Font Definitions */ @font-face {font-family:"MS Mincho"; panose-1:2 2 6 9 4 2 5 8 3 4; mso-font-alt:"\FF2D\FF33 \660E\671D"; mso-font-charset:128; mso-generic-font-family:modern; mso-font-pitch:fixed; mso-font-signature:-536870145 1791491579 18 0 131231 0;} @font-face {font-family:"Cambria Math"; panose-1:2 4 5 3 5 4 6 3 2 4; mso-font-charset:0; mso-generic-font-family:roman; mso-font-pitch:variable; mso-font-signature:-536870145 1107305727 0 0 415 0;} @font-face {font-family:"\@MS Mincho"; panose-1:2 2 6 9 4 2 5 8 3 4; mso-font-charset:128; mso-generic-font-family:modern; mso-font-pitch:fixed; mso-font-signature:-536870145 1791491579 18 0 131231 0;} /* Style Definitions */ p.MsoNormal, li.MsoNormal, div.MsoNormal {mso-style-unhide:no; mso-style-qformat:yes; mso-style-parent:""; margin:0in; margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:12.0pt; font-family:"Times New Roman","serif"; mso-fareast-font-family:"MS Mincho"; color:black;} a:link, span.MsoHyperlink {mso-style-unhide:no; color:blue;} a:visited, span.MsoHyperlinkFollowed {mso-style-unhide:no; color:blue;} .MsoChpDefault {mso-style-type:export-only; mso-default-props:yes; font-size:10.0pt; mso-ansi-font-size:10.0pt; mso-bidi-font-size:10.0pt;} @page WordSection1 {size:8.5in 11.0in; margin:1.0in 1.25in 1.0in 1.25in; mso-header-margin:.5in; mso-footer-margin:.5in; mso-paper-source:0;} div.WordSection1 {page:WordSection1;} --> Allan Sindelar al...@sindelarsolar.com NABCEP Certified PV Installation Professional NABCEP Certified Technical Sales Professional New Mexico EE98J Journeyman Electrician Founder (Retired), Positive Energy, Inc. 505 780-2738 cell Ā _______________________________________________ List sponsored by Redwood Alliance List Address: RE-wrenches@lists.re-wrenches.org Change listserver email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out or update participant bios: www.members.re-wrenches.org
_______________________________________________ List sponsored by Redwood Alliance List Address: RE-wrenches@lists.re-wrenches.org Change listserver email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out or update participant bios: www.members.re-wrenches.org