Hi Jason, We've used the IGS on 3 or 4 systems now, and wouldn't go back to WEEBs. We just can't understand why this wasn't figured out before...
Howie -- Howie Michaelson NABCEP Certified Solar PV Installer™ Catamount Solar, LLC Renewable Energy Systems Sales and Service VT Solar Electric & Hot Water Incentive Partner http://www.CatamountSolar.com 802-272-0004 On Tue, September 10, 2013 4:43 pm, Jason Szumlanski wrote: > http://ironridge.com/ig > > Any first impressions on this new product? > > WEEBs require replacement after modules are removed for service. I wonder > of the IronRidge mid-clamps biting into the same module frame locations > after service have been tested and approved. Moving the module to bite > into > new holes in the frame is impractical, so I hope this has been addressed. > > Otherwise, this looks like a simplified approach to module and rail > grounding. > > J > ason Szumlanski > Fafco Solar _______________________________________________ List sponsored by Home Power magazine List Address: RE-wrenches@lists.re-wrenches.org Change email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org