I have a client who fully discharged a pair of SunXtender PVX3050T 6V batteries. They were about one year old. They had no load voltages of 1.77 and 0.87 V respectively. I have ordered him a new pair but I wondered if they could be resuscitated to some degree and be used for some odd purpose around the shop. I tried to charge them using a Vector VEC1095A charger on the AGM setting: they took about 7.5 A at 14.4 V for about 5 minutes and then shut down. I am now desulphating them, which I think takes the better part of a day. And I then plan to run them through another charge cycle Is there any thing else that I can do to get them in some sort of serviceable shape? - Peter Peter T. Parrish, Ph.D., President California Solar Engineering, Inc. 820 Cynthia Ave., Los Angeles, CA 90065 CA Lic. 854779, NABCEP Cert. 031806-26 <mailto:peter.parr...@calsolareng.com> peter.parr...@calsolareng.com Ph 323-258-8883, Mobile 323-839-6108, Fax 323-258-8885
_______________________________________________ List sponsored by Home Power magazine List Address: RE-wrenches@lists.re-wrenches.org Options & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org