hey guys, thanks for all the great feedback! good suggestions, much appreciated! these are a very robust comp shingle and are ok'd for as low as a 2:12 pitch. that 'self-sealing strip' activates in warm weather and basically seals these suckers down for good! matt, fyi, apparently UL tested these and after the self-sealing strip was set, subjected them to two hours of sustained 177 km/h wind with no damage. the mfg, Malarkey warrants them with a 161 km/h wind warranty.bill h, just so happens that these shingles are called 'the alaskan'. no doubt these are the ones your roofer installed and 'warned' you about.august, i've seen that product before, but haven't tried it yet. thanks for reminding me about it thou, as i may have a flat roof job where i could try it out. i'm quite confidant in my l-foot mounting method, so i have no issue going that route for this one. i'm just trying to use flashings more often, when possible. thanks again to all the feedback. by the way, who is bennett? ;) bennDayStar Renewable Energy Inc. b...@daystarsolar.ca780-906-7807 HAVE A SUNNY DAY
From: aug...@luminalt.com Date: Thu, 7 Oct 2010 16:01:52 -0700 To: re-wrenches@lists.re-wrenches.org Subject: Re: [RE-wrenches] lifting shingles Hi Bennett/Bill - A 2:12 roof is 9.5 degrees. You might consider the ChemCurb product which I believe is good up to about 10 degrees: http://www.chemlinkinc.com/docs/brochure/chemcurb_v5p4.pdf We use these all the time and I feel that they provide a very robust seal. I've never used them on comp shingles but I imagine that you could use a little extra M-1 to glue them down to assure that the self-leveling one part sealant doesn't leak out between the shingle layers. -August August Goers Luminalt Energy Corporation 1320 Potrero Avenue San Francisco, CA 94110 m: 415.559.1525 o: 415.641.4000 aug...@luminalt.com From: re-wrenches-boun...@lists.re-wrenches.org [mailto:re-wrenches-boun...@lists.re-wrenches.org] On Behalf Of Bill Hoffer Sent: Thursday, October 07, 2010 10:30 AM To: RE-wrenches Subject: Re: [RE-wrenches] lifting shingles Bennett I have a roof similar to the one you described. It was designed for coastal regions of Alaska, heat-freeze cycling and high winds. Roofer warned me that I better plan my penetrations because after season in the sun I would never be able to lift the shingle again! That being said have you tried a hot knife? L feet seem like the way to go! Good luck! Bill On Oct 7, 2010 2:05 AM, "benn kilburn" <b...@daystarsolar.ca> wrote: > > salute, i was inspecting a (~3yr old) 2/12 pitch roof for an upcoming install that was going to have flashed roof connection points and noticed that i could not lift up any of the shingles for installing the flashing. the sealing strip that holds the upper shingle to the one below it, is aggressively stubborn. i tried several in the area of the array location and they are all sealed down very well, much better than any other comp shingle i've come across, which typically lift and separate from the 'sticky strip' with a careful little tug on the shingle. all the ones i tried began to tear the back off the top shingle that i was trying to lift. i'm told these are a higher quality comp shingle and are well suited for low pitch roofs, they have a 35 yr warranty. > i contacted the shingle mfg. tech support and after explaining what i was doing his suggestion was literally "try lifting them when its warm out then try when its cold out, see if that works.".... thanks tips! > my first thought was to use a torch to heat and soften up the shingles' sealing strips that i needed to lift. i'm not surprised that the shingle tech did not endorse this method. i'm not thrilled about it either. just having a propane bottle and torch on the roof, risk of overheating (burning) the shingles, extra time to do this, are things i'd prefer to avoid. > i'm sure if done carefully this method would work, but i'm a little more cautious than just trying it without asking around so i've been contacting a few roofers i've worked with, as well i'm wondering if any of you have come across this issue of having to lift particularly well-sealed comp shingles and how you have dealt with it. > if the consensus is to stay away from the torch then i'm prepared to go with the good ol' l-feet on this one. > cheers,benn > DayStar Renewable Energy Inc. b...@daystarsolar.ca780-906-7807 HAVE A SUNNY DAY > > > > > > _______________________________________________ List sponsored by Home Power magazine List Address: RE-wrenches@lists.re-wrenches.org Options & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org
_______________________________________________ List sponsored by Home Power magazine List Address: RE-wrenches@lists.re-wrenches.org Options & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org