We found once we removed the BFS watering caps, that the 5 gal jug, and tubing 
made an excellent manual filling system.

R. Walters
[email protected]
Solar Engineer




On Dec 10, 2009, at 8:44 PM, frenergy wrote:

>     For all of the rest of us Bozos that still manually water cells, try 
> using a set-up used by those who have made their own beer.  It's called a 
> bottle filler in beer making, this is connected to a "racking cane" via 4-6 
> feet of 3/8" clear tubing. I hang a one gallon jug of distilled water 2-3 
> feet above the bank, insert the racking cane (which is just a section of 
> rigid tubing with a bend in it) into jug, bottle filler is on the other 
> cell-filling end of the tubing.
>  
>         Once you've started the siphon simply insert the bottle filler into 
> each cell far enough to start water to flow from jug to cell.  You can easily 
> watch progress of filling, when full, lift up on bottle filler, distilled 
> water stops flowing...done. On to next cell.  This method takes me about 
> 10-12 seconds to accurately fill each of my 1200 Ahr HUP cells in one attempt 
> as filling visibility is good.
>  
>         Yes, you'll need to change the jug a few times...usually 3 times for 
> my pack (1200 Ahrs @ 24V).  The shut off on the bottle filler is pretty 
> positive.
>  
> Bill
> Feather River Solar Electric
>  
>  
> ----- Original Message -----
> From: Joel Davidson
> To: RE-wrenches
> Sent: Thursday, December 10, 2009 11:07 AM
> Subject: **Possible_Spam** Re: [RE-wrenches] Battery Automatic Watering
> 
> On-grid. The IBE lead-antimony cells already installed. So far Wrench 
> feedback is automatic watering systems are unreliable. The watering system 
> that IBE sells to its forklift customers requires the user to manually turn 
> it on and off because the feeder cap float valve does not seal tightly and 
> the drips add up resulting in overfilled cells and a mess.
>  
> Joel Davidson
> ----- Original Message -----
> From: [email protected]
> To: RE-wrenches
> Sent: Thursday, December 10, 2009 10:03 AM
> Subject: Re: [RE-wrenches] Battery Automatic Watering
> 
> On grid or off grid Joel? If grid tied /w battery backup, use lead calcium 
> wet cells. They only need watering about every 18 months.
> 
> Todd
> 
> 
> On Wednesday, December 9, 2009 6:14pm, "Joel Davidson" 
> <[email protected]> said:
> 
> > Wrenches,
> > 
> > We installed 48 each IBE 1-85N-15 cells (24 in series in 2 Direct Power &
> > Water battery boxes). We do not want to use Hydrocaps. Your suggestions for
> > an automatic watering system would be most appreciated. Thanks in advance.
> > 
> > Happy Holidays.
> > Joel Davidson
> > 
> > _______________________________________________
> > List sponsored by Home Power magazine
> > 
> > List Address: [email protected]
> > 
> > Options & settings:
> > http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org
> > 
> > List-Archive: 
> > http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org
> > 
> > List rules & etiquette:
> > www.re-wrenches.org/etiquette.htm
> > 
> > Check out participant bios:
> > www.members.re-wrenches.org
> > 
> > 
> 
> 
> _______________________________________________
> List sponsored by Home Power magazine
> 
> List Address: [email protected]
> 
> Options & settings:
> http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org
> 
> List-Archive: 
> http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org
> 
> List rules & etiquette:
> www.re-wrenches.org/etiquette.htm
> 
> Check out participant bios:
> www.members.re-wrenches.org
> 
> 
> 
> _______________________________________________
> List sponsored by Home Power magazine
> 
> List Address: [email protected]
> 
> Options & settings:
> http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org
> 
> List-Archive: 
> http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org
> 
> List rules & etiquette:
> www.re-wrenches.org/etiquette.htm
> 
> Check out participant bios:
> www.members.re-wrenches.org
> 
> 
> 
> 
> No virus found in this incoming message.
> Checked by AVG - www.avg.com 
> Version: 8.5.426 / Virus Database: 270.14.102/2556 - Release Date: 12/10/09 
> 07:36:00
> _______________________________________________
> List sponsored by Home Power magazine
> 
> List Address: [email protected]
> 
> Options & settings:
> http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org
> 
> List-Archive: 
> http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org
> 
> List rules & etiquette:
> www.re-wrenches.org/etiquette.htm
> 
> Check out participant bios:
> www.members.re-wrenches.org
> 

_______________________________________________
List sponsored by Home Power magazine

List Address: [email protected]

Options & settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules & etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org

Reply via email to