On 02/21/2014 05:58 PM, Kurt Bauer wrote:

> Too easily find the logs from various servers apart I added a custom
> LogIdent parameter per Server, which works as expected. The problem now
> is, that Radiator appends the pid in square brackets to the LogIdent,
> which means, that the central tool identifies a new source whenever
> radiator is restarted, as the LogIdent as a whole changes.
> Is there away to omit the pid?

Hello Kurt,

have you tried using for example, cons as LogOpt option value? It
appears this option is ignored by the recent Sys::Syslog modules.

> I tried with just leaving LogOpt empty, which apparently doesn't work.

As a more permanent solution, I think an empty value can be allowed by
Radiator for LogOpt to turn off any non-default options.

Thanks,
Heikki


-- 
Heikki Vatiainen <h...@open.com.au>

Radiator: the most portable, flexible and configurable RADIUS server
anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald,
Platypus, Freeside, TACACS+, PAM, external, Active Directory, EAP, TLS,
TTLS, PEAP, TNC, WiMAX, RSA, Vasco, Yubikey, MOTP, HOTP, TOTP,
DIAMETER etc. Full source on Unix, Windows, MacOSX, Solaris, VMS,
NetWare etc.
_______________________________________________
radiator mailing list
radiator@open.com.au
http://www.open.com.au/mailman/listinfo/radiator

Reply via email to