On Tue, Oct 24, 2000 at 09:46:44AM +0200, Urban wrote:
> Just the first Ascend-Data-Filter is in the respone from
> the "radpwtst -trace"
> 
> Does any one know if this is bugg in Radiator or if I'm not doing it right.
There was a bug in one radiator version that disallowed multiple attributes
with the same name at least when using LDAP. I patched it and reported to
the mailing list so it should be in the lastest version.

> -- Urban
bye,

 -christian-

-- 
Christian Hammers    WESTEND GmbH - Aachen und Dueren     Tel 0241/701333-0
[EMAIL PROTECTED]     Internet & Security for Professionals    Fax 0241/911879
           WESTEND ist CISCO Systems Partner - Premium Certified

===
Archive at http://www.starport.net/~radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.