Hi Edgar,
The Xilinx Virtex ML507 model uses 2 different interrupt controllers:
- Universal Interrupt Controller
- Xilinx OPB Interrupt Controller
Both are connected to the same CPU IRQ line, IRQ#3 (PPC40x_INPUT_CINT):
108 uicdev = qdev_new(TYPE_PPC_UIC);
109 ppc4xx_dcr_realize(PPC4xx_DCR_DEVICE(uicdev), cpu, &error_fatal);
110 object_unref(OBJECT(uicdev));
111 uicsbd = SYS_BUS_DEVICE(uicdev);
112 sysbus_connect_irq(uicsbd, PPCUIC_OUTPUT_INT,
113 qdev_get_gpio_in(DEVICE(cpu), PPC40x_INPUT_INT));
240 cpu_irq = qdev_get_gpio_in(DEVICE(cpu), PPC40x_INPUT_INT);
241 dev = qdev_new("xlnx.xps-intc");
242 qdev_prop_set_uint32(dev, "kind-of-intr", 0);
243 sysbus_realize_and_unref(SYS_BUS_DEVICE(dev), &error_fatal);
244 sysbus_mmio_map(SYS_BUS_DEVICE(dev), 0, INTC_BASEADDR);
245 sysbus_connect_irq(SYS_BUS_DEVICE(dev), 0, cpu_irq);
How is the hardware wired, is it using an OR gate?
I couldn't figure it out looking here:
* https://docs.xilinx.com/v/u/en-US/ug347
*
https://www.xilinx.com/content/dam/xilinx/support/documents/boards_and_kits/ml50x_schematics.pdf
Thanks,