Chuang,

On Tue, Dec 13, 2022 at 09:35:07PM +0800, Chuang Xu wrote:
> Here are the test results:
> test vm info:
> - 32 CPUs 128GB RAM
> - 8 16-queue vhost-net device
> - 16 4-queue vhost-user-blk device.
> 
>       time of loading non-iterable vmstate
> before                about 210 ms
> after         about 40 ms

It'll be also great if you can attach more information in the cover letter
in the next post.  For example:

  - Per your investigation, what's the major influential factor for the
    memory updates?  Besides the number of devices, does the number of
    queues also matter?  Is there anything else?

  - Total downtime comparison (only if above is only part of the downtime)

  - The nic used in the test.

Thanks,

-- 
Peter Xu